Logging off the serial console port and disconnecting the serial cable

3

NOTE

The addresses 10.0.0.0 through 10.0.0.255 are reserved and used internally by the Brocade DCX 8510-4. External IPs must not use these addresses.

3. Set up the CP0 IP address by entering the ipaddrset -cp 0 command:

swDir:admin> ipAddrSet -cp 0

Enter the information at the prompts.

4. Set up the CP1 IP address by entering the ipaddrset -cp 1 command:

swDir:admin> ipAddrSet -cp 1

Enter the information at the prompts.

This is a sample IP configuration:

swDir:admin> ipaddrset -chassis

Ethernet IP Address [0.0.0.0]: 192.168.1.1

Ethernet Subnetmask [0.0.0.0]: 255.255.255.0 Fibre Channel IP Address [0.0.0.0]:

Fibre Channel Subnetmask [0.0.0.0]: Issuing gratuitous ARP...Done. Committing configuration...Done.

swDir:admin> ipaddrset -cp 0 Host Name [cp0]:

Ethernet IP Address [10.77.77.75]: 192.168.1.2

Ethernet Subnetmask [0.0.0.0]: 255.255.255.0

Gateway IP Address [0.0.0.0]: 192.168.1.254 IP address is being changed...Done. Committing configuration...Done.

swDir:admin> ipaddrset -cp 1 Host Name [cp1]:

Ethernet IP Address [10.77.77.74]: 192.168.1.3

Ethernet Subnetmask [0.0.0.0]: 255.255.255.0

Gateway IP Address [0.0.0.0]: 192.168.1.254

IP address of remote CP is being changed...Done. Committing configuration...Done.

Logging off the serial console port and disconnecting the serial cable

You can use the serial port to monitor error messages through the serial connection. If the serial port is no longer required, use the logout command to log out of the serial console, remove the serial cable, and replace the plug in the serial port.

Establishing an Ethernet connection to the Brocade DCX 8510-4

After using a serial connection to configure the IP addresses for the Brocade DCX 8510-4, you can connect the active CP blade to the local area network (LAN).