Heath Zenith 598-1283-00 Wiring, Horizontal Junction Boxes Only, Recommended Grounding Method

Models: 598-1283-00

1 24
Download 24 pages 4.87 Kb
Page 3
Image 3
Horizontal Junction Boxes Only:

Horizontal Junction Boxes Only:

 

 

Ground

Fixture

 

Screw

Wire

 

Screw

Fixture

Path

 

Black

Light

Green WIRING Fixture or Bare

White

Screw

Junction

Box

Screws

Remove ground screw and 2 fixture screws from the mounting plate. Flip plate over. Re-insert ground screw. Insert the 2 fixture screws in the holes near the junction box screws holes. Wire path must be located as shown above.

White

Black

Green or Bare

One Motion Light

LightLight

Fixture Fixture

Two Motion Lights

WIRING

Note: All wiring should be run in accordance with the National Electrical Code through conduit or another acceptable means.

Contact a qualified electrician if there is any question as to the suitability of the system.

Recommended Grounding Method CAUTION: DO NOT connect the RED wire unless you want to control other lights from the motion sensor.

Twist the junction box wires and the fixture wires together as shown below. Secure with wire connectors. If you have a metal junction box, you may not need the green“pigtail”.If you are unsure about the grounding method, consult your local building code.

Connect the fixture wires to the wires in the junction box. Twist the wires together and secure with wire connectors.

Recommended Grounding Method

Use a green ground “pigtail” (not provided) and twist one end together with the bare fixture wire and the box ground wire. Secure with a wire connector. Secure the other end of the "pigtail" with the GND screw on the mounting plate.

Black to black

White to white

598-1283-00

Page 3
Image 3
Heath Zenith 598-1283-00 warranty Wiring, Horizontal Junction Boxes Only, Recommended Grounding Method, Black to black