OPERATION

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Security

5 or 10 Minutes

 

x

Automatic

Dusk-to-Dawn

 

x

Override

 

 

 

Manual

Until Dawn*

 

x

Override

 

 

 

* resets to Security mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

MANUAL override MODE

Adjustment of Coverage Area

The sensor on this light fixture detects “motion” by the movement of heat across the coverage area.However, following are examples of objects that also produce heat and can cause the sensor to trigger:

• Pools of Water

• Air Conditioners

• Dryer Vents

• Animals

• Heating Vents

• Automobile Traffic

If you suspect that a heat source of this type is trig- gering the sensor, reduce the sensitivity.

SPECIFICATIONS

Range

Up to 30 ft. (9.1 m) [varies

 

with surrounding tempera-

 

ture].

Manual Override mode can only be activated at night when the ON-TIME switch is set to the 5 or 10 minute position.

Flip the light switch off for one sec- ond then back on to change from SECURITY mode to MANUAL OVERRIDE mode.

To return to SECURITY mode, either:

turn the light off for one minute then turn it on, or...

daylight will automatically reset the light to SECURITY mode.

1 Second OFF

then...

... back on.

Sensing Angle

180°

Electrical Load

Up to 180 Watt Maximum

 

Tungsten Incandescent

 

or 5 Watt Maximum LED

 

(Lights of America model

 

2025LEDE12).

Bulb Type

E12 Candelabra Base,

 

Type “B”, 60 Watt Maximum

 

Tungsten Incandescent or

 

LED model 2025LEDE12

 

1.5 Watt.

Sensor Capacity

360 Watt (3.0 A) Maximum

 

Tungsten Incandescent

Power Requirements ....

120 VAC, 60 Hz

Operating Modes

TEST, SECURITY, AUTO-

 

MATIC OVERRIDE and

Mode Switching Summary

 

 

TEST

 

 

 

 

 

ON-TIME Switch at 5 or 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

minutes

 

SECURITY

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

 

MODE

 

 

 

 

 

 

Flip light switch off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for one second then

 

MANUAL MODE

 

 

 

back on*

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time the control will be in the SECURITY mode.

 

MANUAL OVERRIDE

ON-Timer

5 or 10 minutes

Test Timer

5 Seconds

Automatic

 

Override Timer

Dusk-to-Dawn

Manual

 

Override Timer

Until Dawn

6

598-1338-03

Page 6
Image 6
Heath Zenith 9600LED series warranty Operation, Manual override Mode Adjustment of Coverage Area, Specifications