SPECIFICATIONS

Range

Up to 30 ft. (9.1 m)

 

[varieswithsurrounding

 

temperature]

Sensing Angle. . .

Up to 180°

Electrical Load. . .

See rating on fixture

 

for maximum wattage

Sensor Capacity . .

Upto360Watts(3.0A.)

 

Maximum Tungsten

 

Incandescent

Power Requirements 120 VAC, 60 Hz

Operating Modes. .

TEST, AUTO, and

 

MANUAL MODE

Time Delay . . . .

1, 5, 10 minutes

DualBrite® Timer. .

Off, 3, 6 hours, dusk-to

 

dawn

HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

TROUBLESHOOTING GUIDE

SYMPTOM

POSSIBLE CAUSE

 

 

Light will not

1. Light switch is turned off.

come on.

2. Bulb is loose or burned out.

 

3.

Fuse is blown or circuit breaker

 

 

is turned off.

 

4.

Daylight turn-off is in effect

 

 

(recheck after dark).

 

5.

Incorrect circuit wiring, if this is

 

 

a new installation.

 

 

Light comes on

1. Light control may be installed in

in daylight.

 

a relatively dark location.

 

2.

Light control is in Test. (Set

 

 

control switch to an ON-TIME

 

 

position.)

 

 

Light comes on

1. Lightcontrolmaybesensingsmall

for no apparent

 

animals or automobile traffic

reason.

 

(Reduce sensitivity).

 

2.

Sensitivity is set too high. (Re-

 

 

duce sensitivity.)

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

 

Light stays on

1. The sensor is pointed toward

continuously.

 

a heat source like an air

 

 

vent, dryer vent, or brightly-

 

 

painted heat-reflective surface.

 

 

(Reduce sensitivity.)

 

2.

Light control is in Manual Mode.

 

 

(Switch to Auto.)

 

3.

Light control is in DualBrite®

 

 

mode.

 

 

4.

Sensitivity is set too high. (Re-

 

 

duce sensitivity.)

 

 

 

Light flashes

1.

Light control is in the Test

on and off.

 

mode and

warming up.

 

 

(Flashing is

normal under

 

 

these conditions).

 

2.

Heat being reflected from other

 

 

objects may be affecting the

 

 

sensor. (Reduce sensitivity.)

 

 

 

 

595-5628-08