DualBrite® Motion

Sensing Diecast

Lantern

SL-4290 Series

Meets the ENERGY STAR® guidelines when DualBrite® function is off.

OPERATION

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Min

 

x

Manual

To Dawn*

 

x

Accent

3,6 Hr. to Dawn

 

x

* resets to Auto Mode at dawn.

Note: When first turned on wait about 1 1/2 minutes for the circuitry to calibrate.

TEST

Set the ON-TIME switch ON-TIMEon the bottom of the cover

plate to TEST.

TEST 1 5 10 MIN

Questions or problems? Before returning to your retailer, refer to the troubleshooting guide in this manual or call our technical ser- vice department at 1-800-858-8501 (English speaking only), 7:30 am to 4:30 pm, CST, Monday – Friday.

Features

AUTO

Set ON-TIME switch to ON-TIME1, 5, or 10 minutes.

TEST 1 5 10 MIN

MANUAL MODE

Light comes on when motion is detected.

Automatically turns light off.

Dusk Accent lighting.

Photocell keeps the light off during daylight hours.

Package Contents

Lantern

Universal Mounting Bracket

Mounting Screws (Includes extra long screw studs for recessed junction box mounting)

Wire Connectors

Manual mode only works at night because daylight re- turns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and

MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.

1Second OFF then...

Requirements

The light control requires 120 volts AC.

If you want to use Manual Mode, the control must be wired through a switch.

Some electrical codes require installa- tion by a qualified electrician.

... back on.

Before installation, record the model number from back of fixture below. Attach receipt in case of possible war- ranty issues.

© 2008 HeathCo LLC

598-1277-02

Page 1
Image 1