Model SL-5511

The Motion Sensor Quartz Security Light turns on 150 watts of quartz-halogen lighting when motion is detected and then, after a selectable period of time, automati- cally turns the lighting off. The built-in photocell keeps the lighting off during daylight hours.

This package includes:

OPERATION

Mode:

On-Time

Works: Day

Night

Test

5 Seconds

x

x

Auto

1, 5, or 10 Min

 

x

Manual

Until Dawn*

 

x

* resets to Auto Mode at dawn.

Note: When first turned on wait about 11/2 minutes for the circuitry to calibrate.

TEST

Put the ON-TIME switch on the bottom

ON-TIME

 

 

 

 

 

 

 

of the sensor in the TEST position.

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Put the ON-TIME switch in the 1, 5,

ON-TIME

 

 

 

 

 

 

 

 

 

 

 

 

 

 

or 10 minute position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 5 1 TEST

 

 

 

 

 

 

 

 

MANUAL MODE

 

 

 

 

 

 

 

 

Cover Plate

 

Gasket

 

Cover

 

Plate

 

4 Screws

 

(2 sizes)

 

Halogen

 

Bulb

 

Sensor

Light Fixture

3 Wire

 

Manual mode only works at night because daylight returns the sensor to AUTO.

Flip the light switch off for one second then back on to toggle between AUTO and MANUAL MODE.

Manual mode works only with the ON-TIME switch in the 1, 5, or 10 position.

1 Second OFF

then...

... back on.

Connectors

Requirements

The light control requires 120-volts AC. Do not con- nect through a dimmer or other electronic switch.

If you want to use Manual Mode, the control must be wired through a switch.

Some codes require installation by a qualified electrician.

This product is intended for use with the enclosed gasket and with a junction box marked for use in wet locations.

The backplate has knockouts so the sensor can be mounted on most junction boxes.

In some applications a universal adaptor plate may be needed. Adaptors are available at Home Centers and Electrical Supply Stores.

Mode Switching Summary

 

TEST

 

 

 

 

 

Move ON-TIME Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to 1, 5, or 10 minutes

 

 

 

 

 

 

 

 

 

AUTO

 

 

 

 

 

Flip switch off for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

one second then

 

 

 

 

 

 

 

 

back on*
MANUAL MODE

 

 

 

 

 

 

 

*If you get confused while switching modes, turn the power off for one minute, then back on. After the calibration time (11/2 min.) the control will be in the AUTO mode.

© 2007 HeathCo LLC

595-5574-06

Page 1
Image 1
Heath Zenith manual Compact 150 Watt Motion Sensing Halogen, Operation, Model SL-5511, On-Time, Test, Auto, back on