Heath Zenith SL-5511 Installation, Wire the Light Control, CAUTION to avoid fire or burn hazards

Models: SL-5511

1 12
Download 12 pages 14.76 Kb
Page 2
Image 2
INSTALLATION

INSTALLATION

For easy installation, select an existing light with a wall switch for replacement.

For best performance, locate the fixture about 8 ft. (2.4 m) above the ground.

CAUTION: The sensor must be mounted below the lamp housing for wall installations.

Drill out the holes if needed to mount the backplate to the junction box.

To insert the new bulb, push the bulb into the right socket so the bulb fits completely into the left socket.

Check that the bulb is seated properly.

Close the glass cover. Replace screw.

Wire the Light Control

Turn the power to the lighting circuit off at the fuse or circuit breaker box.

Remove the existing light fixture.

Strip about 5/8" insulation from the existing junction box wiring.

Route the light control’s wires through the large hole in the gasket.

Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.

CAUTION to avoid fire or burn hazards:

Allow fixture to cool before touching. The bulb and fixture operate at high temperatures.

Keep fixture at least 2" (5 cm) from combustible materials. Do not aim at objects closer than 3 feet (1 m).

Re-lamp with type T 150W (or less) halogen 120 VAC lamp only.

For under eave installation, the sensor head must be rotated as shown in the next two steps for proper operation and to avoid the risk of electrical shock.

Rotate the sensor head to-

wards the clamp screw joint.

Controls

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clamp Screw Wire the Light Control

Then rotate the sensor head counterclockwise 180° so the controls face down.

Controls CAUTION to avoid fire or burn hazards:

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

Bulb Installation and Relamping

When relamping, turn power off and let the fixture cool.

Remove the screw that holds the glass cover shut. Remove the old bulb by pushing the bulb towards the right until the left side of the bulb is clear of the left socket.

 

 

White to White

Black to Black

 

 

 

Junction box ground wire to Bulb Installation and Relamping green ground wire on fixture. Cover Plate

Gasket

Mount the Light Control

Align the light control cover plate and cover plate gasket and the junction box. Insert and tighten the mounting screws.

If not installed on a weatherproof box or if an adaptor plate is used, caulk the wall plate and mounting surface with silicone weather sealant.

RIGHTWRONG

The halogen light must be mounted horizontally (+/- 4°).

595-5574-06

Page 2
Image 2
Heath Zenith SL-5511 manual Installation, Wire the Light Control, CAUTION to avoid fire or burn hazards, White to White