TEST AND ADJUSTMENT

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute calibration period before it will detect motion. When first turned on, wait 1 1/2 minutes.

For aiming, turn the SENSITIVITY (SENS) control to the mid position and the ON-TIME control to the TEST position.

The detector is less sensitive to motion directly towards it and more sensitive to across motion.

MotionMotion

MotionMotion Sensor

Least Sensitive

Most Sensitive

ON-TIME

TEST 1 5 10 MIN MAX

SENS

Bottom of Sensor

In the test position shown above, the light will turn on for 5 seconds each time motion is detected dur- ing both daylight and darkness.

Avoid aiming the control at:

Objects that change temperature rapidly, such as heat-

 

ing vents or air conditioners. These heat sources

 

could cause false triggering.

Areas where pets or traffic may trigger the control.

Rotate the sensor base left and right to aim the sensor. Adjust the sensor eye up and down to obtain desired coverage range.

Walk through the coverage area noting where you are when the lights turn on.Move the sensor head up, down, or sideways to change the coverage area.

SetSENSITIVITYasneeded. Too much sensitivity may increase false triggering.

Set the amount of TIME the lightsstayonaftermotionisde- tected (1, 5, or 10 minutes).

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Nearby large, light-colored objects reflecting light

may trigger the shut-off feature. Do not point other

lights at the sensor.

110°

7ft

(2.1 m)

30 ft (9.1m)

 

Maximum Range

Maximum

 

Coverage Angle

SPECIFICATIONS

Range . . . . . . . . Up to 30 ft (9.1 m) [varies with surrounding temperature].

Sensing Angle. . . . . Up to 110°

Electrical Load. . . . . Up to 60 Watt Maximum In- candescent

Power Requirements. . 120 VAC, 60 Hz

Operating Modes. . . . TEST, AUTO and MANUAL OVERRIDE

Time Delay . . . . . . 1, 5, 10 minutes Sensitivity . . . . . . Adjustable