Heatiator CB4842IR, CB4236IR K. Install Louvers and Trim, L. Hood, M. Air Shutter Setting

Models: CB4842IR CB4236IR

1 40
Download 40 pages 61.2 Kb
Page 31
Image 31
K. Install Louvers and Trim

K. Install Louvers and Trim

Install optional trim kits and/or surrounds using the instructions included with the accessory.

Use non-combustible materials to cover the gap between the sheet rock and the appliance (if desired).

Do not obstruct or modify the air inlet/outlet grilles.

Leave space to lower the bottom grille and remove the trim door.

L. Hood

Align back edge of hood with attachment clips and press firmly in place.

M. Air Shutter Setting

Air shutter settings should be adjusted by a qualified installer at the time of installation. The air shutter is set at the factory for minimum vertical vent run. Adjust air shut- ter for longer vertical runs.

It takes 16 full turns of the shutter adjustment handle to move the air shutter from fully open to fully closed.

When the air shutter adjustment handle is all the way down, the air shutter is in the closed position.

NOTICE: If sooting occurs, provide more air by opening the air shutter.

Closed

Figure 14.9 Air Shutter

Heatilator • Caliber BV Series • 4040-262 • Rev M • 08/09

31

Page 31
Image 31
Heatiator CB4842IR, CB4236IR owner manual K. Install Louvers and Trim, L. Hood, M. Air Shutter Setting