9 Appliance Preparation |
| |||
A. Install Outside Air Kit Damper Assembly | C. Secure and Level the Appliance | |||
|
|
| ||
CAUTION! Risk of Cuts/Abrasions/Flying Debris. | WARNING! Risk of Fire! Prevent contact with: | |||
Wear protective gloves and safety glasses during installa- | ||||
• Sagging or loose insulation | ||||
tion. Sheet metal edges are sharp. | ||||
WARNING! Risk of Fire/Asphyxiation. DO NOT draw out- | • Insulation backing or plastic | |||
• Framing and other combustible materials | ||||
side combustion air from: |
| Block openings into the chase to prevent entry of | ||
|
|
| ||
• Wall, floor or ceiling cavity. | insulation. Make sure insulation and other materials are | |||
• Enclosed space such as an attic or garage. | secured. | |||
• Close proximity to exhaust vents or chimneys. | DO NOT notch the framing around the appliance | |||
Fumes or odor may result. |
| |||
| standoffs. | |||
• The outside air kit can only be installed on the left side | ||||
Failure to maintain air space clearance may cause | ||||
of the appliance. |
| |||
| overheating and fire. | |||
• Refer to the installation instructions provided with the | ||||
| ||||
kit. |
|
| The diagram shows how to properly position, level, and | |
|
|
| secure the appliance (see Figure 9.2). Nailing tabs are | |
|
|
| provided to secure the appliance to the framing members. | |
|
|
| • Bend out nailing tabs on each side. | |
|
|
| • Place the appliance into position. | |
| Flexible Duct |
| • Keep nailing tabs flush with the framing. | |
| (not supplied) |
| • Level the appliance from side to side and front to | |
|
|
| back. | |
|
|
| • Shim the appliance as necessary. It is acceptable to use | |
|
|
| wood shims underneath the appliance. | |
|
| Outside Air | • Secure the appliance to the framing by using nails or | |
|
| screws through the nailing tabs. | ||
Outside Air |
| Plate | ||
| Assembly | • Secure the appliance to the floor by inserting two screws | ||
Hood | 2 Wire Ties | |||
|
|
| through the bottom front of the appliance. |
• Hearth & Home Technologies Inc recommends using |
|
|
UL181 Class 0 or Class I rigid or flexible ducting. |
|
|
• Secure flex duct with metal tape, screws or wire ties. |
|
|
Figure 9.1 Outside Air Kit Installation |
|
|
B. Gas and Electrical Connections |
|
|
If applicable, ensure that gas and electrical connections |
|
|
are installed at this time. Refer to Sections 11 (Gas Infor- | Nailing Tabs |
|
mation) and 12 (Electrical Information). |
| |
| (both sides) |
|
| Figure 9.2 Proper Positioning and Securing of Appliance |
|
Heatilator • Caliber BV Series • | 23 |