D. Frame the Fireplace

D. Frame the Fireplace

Figure 6.4 shows typical framing using combustible materials (2x4 lumber shown).

Observe all required air space clearances to combustible materials as shown in Figure 6.1 & 6.2.

Framing across the top of fireplace must be above top standoffs.

54 5/8 in. (1387 mm) *

22 1/2 in.

(572 mm) *

*If the interior of the chase will be drywalled, add the thick- ness to this measurement.

REQUIRED!

2 in. (51 mm) minimum air space

clearance around chimney

18 in. (457 mm)

minimum distance

from wall to

fireplace opening.

1/2 in. (13 mm)Manual background Clearance

Figure 6.4 Framing the Fireplace

1/2 in.

Drywall

42-1/2 in.

(1080 mm)

22 1/2 in.

(572 mm) *

1/2 in. (13 mm)

Clearance

Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12