12 Accessories

12 Accessories

A. Gas Log/Lighter Provision

Warning! Fire and/or Asphyxiation Risk! Use with solid wood fuel or decorative gas appliance only. Gas fire generates fumes.

DO NOT install unvented gas logs

Damper must be locked fully open when gas logs are installed

A certified gas log lighter or decorative gas log set can be installed in this fireplace.

Maximum input is 100,000 BTU/hr.

Decorative gas appliance must be certified to ANSI Z21.60 “Standard for Decorative Gas Appliances for Installation in Vented Fireplaces”.

Must be installed in accordance with the National Fuel

Gas Code, ANSI Z223.1.

A gas log set must incorporate a gas shutoff.

Gas Log set requires the damper to be locked fully open.

A listed automatic damper system with safety interlock may be used in this fireplace with only compatible, listed gas log sets. See damper system manufacturer’s insturctions.

Knockouts are provided on both sides of the fireplace and in refractories for 1/2 in. (13 mm) iron pipe.

Seal refractory around pipe with fireplace mortar or a non-combustible sealant.

B. Wood Burning Inserts

Warning! Risk of Fire! Improper installation of wood in- serts may cause fireplace or chimney system to overheat.

If a wood burning insert is being installed in this fireplace, Hearth & Home Technologies recommends full reline of the chimney.

Cooling air openings at the top of the chimney must not be obstructed in any manner.

Hearth & Home Technologies recommends securing the reline at the top of the flue and using the cap certified for use with this fireplace system.

Firebox

Refractory A. Gas Log/Lighter ProvisionGas Code, ANSI Z223.1.B. Wood Burning InsertsManual backgroundManual backgroundManual backgroundManual backgroundManual background

Seal with Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background fireplace mortar Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background or non-combust- Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background ible sealant Manual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual backgroundManual background

Outer shell of fireplace

Manual background Maintain air clearance Manual background to combustibles.

Combustible materials

Gas line Manual background

Repack insulation knockout

Gas line

Manual background 4 in. Manual background (102 mm)

1 1/2 in. (38 mm) Manual background air space around

pipe

Combustible materials may be located at zero clearance to gas line beyond 4 in. (102 mm) from fireplace side.

Figure 12.1 Gas Line Installation

Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12

41

Page 41