Heatiator I80 owner manual E. Install the Attic Insulation Shield, Fire Risk

Models: I80

1 56
Download 56 pages 59.36 Kb
Page 23
Image 23
E. Install the Attic Insulation Shield

E. Install the Attic Insulation Shield

Manual background WARNING

Fire Risk

DO NOT pack insulation or other combustibles: between ceiling firestops; between chimney and attic insulation shield.

ALWAYS maintain specified clearances around chimney and ceiling firestop systems.

Install ceiling firestops as specified.

Failure to keep insulation or other material away from chimney pipe may cause fire.

An insulation shield must be installed when there is a pos- sibility of insulation coming into contact with the factory built chimney system. Installation of a ceiling firestop is required (see Figures 5.7 and 5.8).

Roll the shield (around the chimney if already installed) until you have a 3 in. (76 mm) overlap and the three holes on each side match up (large holes on top).

Insert three screws into the matching holes to form a tube.

Bend three tabs on the bottom of the tube inward to 90° to maintain chimney clearance. See Figure 5.6.

Rest the insulation shield on the ceiling firestop below.

Bend the three short tabs at the top of the shield inward to 90° to maintain the 2 in. (51 mm) clearance from the chimney.

Bend the remaining top tabs to just meet the pipe.

 

 

 

 

Bend remaining tabs

 

 

 

 

to rest against pipe to

Bend

 

inward

prevent insulation

90°

 

from falling in.

 

 

 

 

 

Insert three

 

 

 

 

screws

Manual background 3 in. (76 mm) overlap

Figure 5.6 Prepare Attic Insulation Shield

 

 

Tabs bent in to

 

Pipe

rest against pipe

 

 

 

 

Attic Insulation Shield

 

 

17 in. (432 mm)

 

6 Tabs bent

diameter

 

in 90°

Ceiling Firestop

 

 

Insulation

Pipe

Insulation

13 in.

 

 

(330 mm)

 

 

Figure 5.7 Install Attic Insulation Shield Above the Ceiling

 

 

Tabs bent in to

 

 

rest against pipe

 

Pipe

 

 

 

Attic Insulation Shield

 

 

17 in. (432 mm)

 

 

diameter

 

6 Tabs bent

 

 

in 90°

 

Insulation

 

Insulation

13 in.

Pipe

Ceiling Firestop

(330 mm)

 

 

Figure 5.8 Install Attic Insulation Shield Below the Ceiling

If you wish to make a custom shield or barrier, follow these guidelines:

Metal is preferred, although any material stiff enough to hold up against the insulation can be used.

The shield or barrier must be tall enough to extend above the insulation and prevent blown-in insulation from spilling into the cavity.

Maintain specified cleaances around chimney.

Check instructions and local codes for further details.

Heatilator • I80 CAN-US4013-203 Rev F • 04/08

23

Page 23
Image 23
Heatiator I80 owner manual E. Install the Attic Insulation Shield, Fire Risk