Heatmaster 201 manual Mcba For Specialists Installer, Service Engineer, Display, Factory setting

Models: 201

1 28
Download 28 pages 23.53 Kb
Page 21
Image 21
Manual background

MCBA FOR SPECIALISTS: INSTALLER, SERVICE ENGINEER

Key

STEP

STEP

STEP

STEP

STEP

STEP

STEP

STEP

STEP

STEP

STEP

STEP

STEP

STEP

STEP

Display

Description of the parameters

Heating lock time (sec x 10.2)

Hot water lock time (sec x 10.2)

Lock time to switch from hot water mode to heating mode (sec x 10.2)

Difference T1 - T2 for modulation

BUS address (-1 = disabled)

Increase the primary temperature value to generate hot water (relative to the hot water temperature)

1st digit: heating circuit (AM3-114-way valve)

0 = disabled

5 = enabled

2nd digit: the demand for heat comes from: 0 = room thermostat

1st digit: Hot water circulator pump (= 1)

2nd digit: tank with NTC3 sensor (= 2)

Manual fan speed (- 01 = modulation)

1st digit: PWM pump operating speed

2nd digit: PWM pump speed during time-delay

Holding temperature

Maximum temperature for the heating circuit outlet (AM3-114-way valve)

Minimum temperature for the heating circuit outlet (AM3-114-way valve)

Hysteresis of the heating circuit outlet temperature (AM3-114-way valve)

1st digit: Special pump (0 = disabled)

2nd digit: Minimum disable cycle (0 = disabled)

Factory setting

00

00

00

05

-01

05

00

12

-01

11

00

60

30

01

00

19

Page 21