Henny Penny

5-11. TEMPERATURE PROBE

REPLACEMENT (Continued)

501

Model 580

3.Remove the Control Board.

4.Remove probe connections from PC board.

5.Using a ½” wrench, remove the nut on the compression fitting.

6.Remove the probe from the cookpot.

7.Place the nut and new ferrule on the new probe and insert the probe into the compression fitting until it extends

.475 inches (12 mm) into the cookpot.

8.Tighten hand-tight and then a half a turn with wrench.

Excess force damages the probe.

9.Connect new probe to PC board and replace Control Panel.

10.Replace shortening.

11.Turn power “ON” and check out fryer.

5-11

Page 11
Image 11
Henny Penny 580 manual Temperature Probe, Replacement