Be sure capillary bulb of high limit is positioned as not to interfere with carrier or when cleaning the cookpot wall, or damage to capillary tube could result.

15.With excess capillary line pulled out, tighten smaller nut.

16.Replace front panel.

17.Refill with shortening.

There are two fuse holders on each model of the electric fryers. There are no fuse holder assemblies for the gas models other than that at the main power source.

Remove electrical power supplied to the fryer by unplugging the unit, or turning off the wall circuit breaker or electrical shock could result.

CONTROL PANEL FUSES 3 Phase Check from #54 to #55 and #68 to #69 on fuse assembly, or the fuse can be removed to check for a closed circuit. If not, replace the fuse (HP# EF02-007).

Page 4
Image 4
Henny Penny 580 manual