CSL CSM CSB
ELECTRICAL SUPPLY
Standard electrical supply for all
NOTE: The power connections are located behind the service door (see section
Each unit requires a separate fused service according to the following table: (3 phase only)
Model | Voltage | Phase | Amps | Load |
208V | 3 | 27 | 9.6KW | |
208V | 1 | 46 | 9.6KW | |
240V | 3 | 27 | 9.6KW | |
240V | 1 | 40 | 9.6KW | |
208V | 3 | 52 | 18.6KW | |
240V | 3 | 45 | 18.6KW | |
208V | 3 | 88 | 31.5KW | |
240V | 3 | 76 | 31.5KW | |
208V | 3 | 103 | 37.2KW | |
240V | 3 | 90 | 37.2KW | |
208V | 3 | 175 | 63KW | |
240V | 3 | 152 | 63KW |
NOTE: When the oven is installed it must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electric Code, ANSI/NFPA
Do Not use conduit as a supply ground, or electrical shock could result.
NOTE: All connections must comply with the oven data plate. A separate fused disconnect switch or circuit breaker (not furnished) MUST be installed in the electrical supply line FOR EACH OVEN!
NOTE: The electrical diagram is located behind the service door.
The electric supply terminal block, located behind the service door, is clipped on a mounting rail which is attached to the frame of the unit. The three phases of the power cord are connected to the three gray colored terminals. Ground is con- nected to the
NOTE: The phase sequence does not have to be observed because of the automatic reversing action of the fan motor.
CHANGES IN VOLTAGE
To change voltages of the
1)Air and steam elements
2)Contactor LS5
3)CSM and CSL units - the wires on the control panel transformer and the interior light transformer must be switched to the correct voltage terminals.