Model HMI-103/105

2-3. ELECTRICAL CONNECTION The island warmer is available from the factory wired for 120/208-240 volts (domestic), or 230 volt and 400 volt (international), single or three phase, 3 or 4 wire plus ground (includes neutral). The proper power service cable is provided with domestic units, but not on international units.

This unit must be adequately and safely grounded. Refer to local electrical codes for correct grounding procedures. If unit is not adequately grounded, electrical shock could result.

A separate disconnect switch with proper capacity fuses or breakers must be installed at a convenient location between the unit and the power source.

2-4. ELECTRICALDATATABLE

Model

Volts

Phase

Watts

Amps

Wires

 

HMI-103 120/208 1

2400

11.0

3+G

 

HMI-103 120/208 3

2400

8.0

4+G

 

HMI-103 120/240 1

2600

11.0

3+G

 

HMI-103 120/240 3

2600

7.5

4+G

 

HMI-105 120/208 1

3900

18.0

3+G

 

HMI-105 120/208 3

3900

13.0

4+G

 

HMI-105

120/240 1

4200

17.5

3+G

 

HMI-105

120/240

3

4200

12.0

4+G

 

HMI-103

230

1

2600

11.3

4+G

 

HMI-105

400

3

4200

7.8

4+G

2-2

203

Page 8
Image 8
Henny Penny HMI-105, HMI-103 manual Electricaldatatable