3.Press the Set Switch and the left display flashes “Prob” and “Calib.” The right display shows the actual pot temperature, and the right Up and Down Switches are used for calibration.

4.Press the Set Switch and the left display flashes “AL” and “dur.” The right display shows the duration of this alarm at the end of a cook cycle, and can be adjusted with the right Up and Down Switches.

5.Press the Set Switch and the left display flashes “Hold” and “dur.” The left display shows the duration of the hold alarm at the end of the hold cycle, and can be adjusted with the right Up & Down Switches.

I 6. Press and hold the Set Switch to exit the program mode.

The Special Program Mode allows the operator to initialize the program, or to perform an input/output test.

1.Turn Power Switch off, then press and hold the right Up and Down Switches while turning power switch back on. The left display shows “init” and the right displays shows “sgs.” Press and hold the right Up or Down Switch for five secondsto initialize all settings. Special Program Mode is automatically exited if initialize is done.

2.While in the Special Program Mode, press the Set Switch and the left display shows “10” and the right display shows “test,” then they go blank. By pressing all switches, enables all LED’s and displays. Pressing temp. switch turns on heat. Press and hold Set Switch exits Special Pro- gram Mode.