Temperature Spreader

Model OFE-321,322

2-9. HEATING ELEMENTS

(Continued) 3. Remove the heating element wires from the terminals by removing the nuts and washers. Label each so it can be replaced on the new element in the same position.

4.Remove the bolts from the five element spreaders. The element spreaders will now pull off the elements.

5.Remove the brass nuts and washers which secure the ends of the elements through the frypot wall.

6.Remove the heating elements from the frypot as a group by lifting the far end and sliding them up and out toward the rear of the frypot.

Always install new rubber O-rings when installing heater elements.

7.Install new heating elements with the new O-rings, terminal end first at approximately a 45° angle, slipping the terminals through the front wall of the frypot.

8.Replace the brass nuts and washers on the element terminals. Tighten the brass nuts to 30 foot lbs. of torque.

9.Evenly space the element spreaders on the sides of the elements and reinstall bolts. Place the fifth spreader in the front of the elements as to protect the temperature probe. (Fig.2-1

10.Replace the high limit bulb holder on the top element, and position the bulb between the top and second element midway from side to side, and tighten screw that holds the bulb in place.

11.Reconnect the wires to the appropriate terminal as labeled when they were removed.

Temperature Spreader

Probe

Fig. 2-112. Replace the front control panel.

405

2-6

Page 6
Image 6
Henny Penny OFE-321 manual Temperature Spreader Probe, Heating Elements