Ch 2: Installation and Use of Devices
7.Write inhibition lamp
The four lamps shown above indicate operation status as shown in the following table. When all the four lamps are on, a
Lamp | Lighting |
| Operation status |
|
|
| |
Handle operation lamp | Comes on in green | The cartridge insert/eject handle is usable. | |
|
|
| |
| Goes off | The cartridge insert/eject handle is unusable. | |
|
|
|
|
Cleaning tape use lamp | Comes on in yellow | • | Cleaning required. |
|
| • The cartridge is broken. | |
|
|
|
|
| Goes off | • | Cleaning completed. |
|
| • | Cleaning unnecessary. |
|
|
| |
Blinks in yellow | The cartridge is in operation. | ||
|
|
| |
| Comes on in yellow | The cartridge is being loaded. | |
|
|
| |
Write inhibition lamp | Comes on in orange | The cartridge is | |
|
|
| |
| Goes off | You can write data to the cartridge. | |
|
|
|
|
8.Recording density display lamps
The six lamps indicate operation status as shown in the following table. When all six lamps are blinking, the drive is faulty.
Lamp | Lighting | Operation status | |
|
|
| |
2.61 | Comes on in yellow | Data is recorded in the cartridge with the 2.6 format (up to 2.6GB). | |
| Blinks in yellow | The 2.6 format has been selected.2 | |
6.01 | Comes on in yellow | Data is recorded in the cartridge with the 6.0 format (up to 6.0GB). | |
| Blinks in yellow | The 6.0 format has been selected.2 | |
10.0/15.01 | Comes on in yellow | Data is recorded in the cartridge with the 10.0 format. | |
| Blinks in yellow | The 10.0 format has been selected.2 | |
20.0 | Comes on in yellow | Data is recorded in the cartridge with the 20.0 format (up to 20GB). | |
|
|
| |
| Blinks in yellow | The 20.0 format has been selected.2 | |
Compress | Comes on in yellow | Compressed write is performed. (10.0/15.0 and 20.0 format only) | |
|
|
| |
| Goes off | Compressed write is not performed. | |
|
|
| |
Recording density | Comes on in yellow | The recording density has been changed. | |
change1 (Density |
|
| |
Goes off | The recording density has not been changed. (host selection) | ||
Override) | |||
|
| ||
| Blinks in yellow | The recording density is being changed. | |
|
|
|
1 This function is not supported.
2 Data is recorded in the cartridge with another recording density.
9.Cartridge insert/eject handle Used to insert and eject a cartridge.
Hitachi PC VisionBase 8450H/R Server | 21 |