Multifunctional settings

OPTION menu (continued)

Item

Description

 

 

 

Selecting this item displays the SERVICE menu.

 

Select an item using the buttons ▲/▼, and press the button ► or

 

the ENTER button on the remote control to execute the item.

 

FAN SPEED AUTO ADJUST GHOST FILTER MESSAGE FACTORY RESET

 

FAN SPEED

 

Using the buttons ▲/▼ switches the rotation speed of the cooling

 

fans. The HIGH is the mode for use at highlands etc. Note that the

 

projector is noisier when the HIGH is selected.

 

HIGH ó NORMAL

 

AUTO ADJUST

 

Using the buttons ▲/▼ enables/disables the automatic adjustment.

 

When DISABLE is selected, the automatic adjustment feature is

 

disabled, although rough adjustment is automatically performed

 

depending on the basic setting.

 

ENABLE ó DISABLE

 

• Depending on conditions, such as input image, signal cable to the

 

projector, environment around the projector, etc., the automatic adjustment

 

may not work correctly. In such a case, please choose DISABLE to

 

disable the automatic adjustment, and make adjustment manually.

 

GHOST

SERVICE

1. Select a color element of ghost using the buttons ◄/►.

2. Adjust the selected element using the buttons ▲/▼ to disappear ghost.

FILTER MESSAGE

Use the ▲/▼ button to set the timer for the interval to show the message for cleaning up the air filter.

50h ó 100h ó 200h ó 300h ó TURN OFF

After selecting “50h”, “100h”, “200h”, or “300h”, the message

“REMINDER ***HRS PASSED AFTER THE LAST FILTER CHECK” will appear after the timer reaches the interval time set by the menu. (40) When the “TURN OFF” is chosen, the air filter cleaning message will not appear.

Please check and clean the air filter periodically, even if there is no message. If the air filter becomes to be blocked by dust or others, the internal temperature will rise, which could cause malfunction, or reduce the lifetime of the projector.

It is recommended to choose “100h” in general. Please be careful with the operating environment of the projector and the condition of the air filter, especially when the “200h”, “300h or “TURN OFF” is chosen.

FACTORY RESET

Selecting RESET using the button ▲ performs this function. By this function, all the items in all of menus will collectively return to the initial setting. Note that the items LAMP TIME, FILTER TIME and LANGUAGE are not reset.

RESET ï CANCEL

41