Maintenance

Lamp (continued)

A lamp has a finite product life. Using the lamp for long periods of time could cause the pictures darker or the color tone poor. Note that each lamp has a different lifetime, and some may burst or burn out soon after you start using them. Preparation of a new lamp and early replacement are recommended.

To prepare a new lamp, contact your dealer and tell the lamp type number.Type number = DT00701.

1. Turn the projector off, and unplug the power cord. Allow the lamp to cool for at least 45 minutes.

2. Prepare a new lamp.

If the projector is mounted on the ceiling, or if the lamp has broken, also ask the dealer to replace the lamp.

In the case of replacement by yourself,

 

Claws of lamp cover

After making sure that the projector has cooled

 

 

 

3. adequately, slowly turn over the projector, so

 

 

that the bottom is facing up.

 

 

Please loosen the screw (marked by arrow). Then, unhook

 

4. the claws of the lamp cover and remove the lamp cover.

 

Loosen the 2 screws (marked by arrow) of the lamp,

Screw marked by arrow

5. and slowly pick up the lamp by the handles.

 

 

Insert the new lamp, and retighten firmly two

 

 

6. screws that are loosened in the previous

 

 

process to lock it in place.

 

 

Interlocking the 2 tabs of the lamp cover to

 

 

7. the projector, position the lamp cover on the

Screws marked

projector, and push the center point of two

by arrow

claws to fix the lamp cover. Then retighten

 

Center

firmly the screw of the lamp cover.

 

point

8. Slowly turn the projector so that the top is facing up.

of claws

Tabs

9. Turn the projector on and reset the lamp time using the LAMP TIME function in the OPTION menu (40).

(1)Press the MENU button to display a menu. Only when the EASY MENU has appeared, please perform the next step (2).

(2)Point at the “Go To Advance Menu …” in the menu using ▼/▲ button, then press the ► button.

(3)Point at the “OPTION” in the left column of the menu using ▼/▲ button, then press the ► button.

(4)Point at the ”LAMP TIME” using ▼/▲ button, then press the ► button. A dialog will appear.

(5)Press the ▲ button to select “RESET” on the dialog. It performs resetting the lamp time.

NOTE • Please reset the lamp time only when you have replaced the lamp, for a suitable indication about the lamp.

43