Hitachi CU-HD1000 CCU Power switch, Camera Power switch, Call button, Intercom Level control

Models: CU-HD1000

1 38
Download 38 pages 2.51 Kb
Page 15
Image 15

Facility names and functions

8

11

6

9

 

12

 

 

 

7

27

4

2

3

5

1

10

1CCU POWER switch

CCU power on/off switch.

2CCU POWER LED

Lights when power is on.

3CABLE CHECK LED

OK: CAMERA POWER switch 4 can be

operated.

OPEN: Fiber cable not connected.

SHORT: Excess current in fiber cable.

Note: CAMERA POWER switch 4 is

inoperative when OPEN, SHORT LED is lighted.

4 CAMERA POWER switch

Camera power on/off switch; lights at power on. When the camera power is off, only one channel intercom (CH1) is available.

Press the switch for 3 sec. or more, the camera power turns off.

5 GL ON LED

Lights during genlock operation.

4

Note: When a different frame rate signal is input for genlock, the LED blinks and the signal is ignored.

6R TALLY LED

Lights at red tally input or when sending CALL signal from camera.

7G TALLY LED

Lights at green tally input.

8CALL button

Press to call the camera.

9INTERCOM LEVEL control

Adjusts intercom listening volume.

10TALK ON/OFF switch

Intercom microphone on/off switch.

11PRIVATE/COMM switch

PRIVATE: Communicate with camera only

COMM: Communicate with entire system

12Intercom connector (XLR,5P)

Connection for optional MT-12MF headset.