Hitachi operating instructions Input output signals CU-HD1000, Input signals

Models: CU-HD1000

1 38
Download 38 pages 2.51 Kb
Page 36
Image 36

Specifications

yPower supply voltage

CU-HD1000J

AC100V 50/60Hz

 

CU-HD1000U

AC117V 60Hz

 

CU-HD1000E

AC230V 50Hz

yPower consumption

210W approx. (AC operation, including SK-HD1000,VF-402 and utility POWER)

yAmbient Temperature

Operating:

0 to +40

 

 

Storage:

-20 to +60

yDimensions

216(W)°118(H)°400(D)mm

yMass

7kg approx.

 

 

yMax. Cable length

1km

 

 

■Input output signals (CU-HD1000)

Input signals

GEN LOCK IN

B-BST 0.45Vp-p/75Ω(loop through)

BNC

 

HDTV tri-level sync 0.60Vp-p/75Ω

 

 

(loop through)

 

DIGITAL RET IN1/2/3/4

HD SDI(1080i,720p) or SD SDI

BNC

 

*HD SDI input is same as output format

 

 

1080i : SMPTE292M

 

 

720p : SMPTE296M

 

 

SD-SDI : SMPTE259M

 

ANALOG RET IN1/2

VS or VBS 1.0Vp-p/75Ω(loop through)

BNC

PROMPT IN

VS or VBS 1.0Vp-p/75Ω(loop through)

BNC

INTERCOM(HEAD SET)

-60dBm

XLR-5pin(Female)

COMMUNICATION

 

D-sub 15pin

INTERCOM

0dBm , 600Ωat 4Wire

 

 

0dBu or -15dBu ,200Ωat 2Wire

 

PGM

0dBm/600Ω

 

R/G TALLY

Voltage or contact supply

 

REMOTE 1

1.5Vp-p or

4pin

REMOTE 2

1.5Vp-p

4pin

RS-232C

9600 baud

D-sub 9pin

25