If the lamp goes out while charging, disconnect the power cord, and leave for 3 to 5 minutes before reconnecting. If the problem persists, call for repairs.

Leave 5 minutes between charging batteries as the charger may overheat leading to malfunction.

The battery life is finished if it can only be used for short periods even when fully

charged. Purchase a new battery. Continuing to use a depleted battery may cause the charger to malfunction.

NOTE:

Charging times may be longer depending on the surrounding temperature and battery conditions.

Charge time lamp indications are only a guide, and may vary depending on the surrounding temperature and battery conditions.

Remove the battery from the charger when not in use.

Revitalizing the battery (trickle recharge)

A new battery or a battery that has not been used for extensive periods may not charge completely due to internal chemicals being inert.

Leave the battery inserted in the charger for 8 to 12 hours after charging is complete. The charger automatically “revitalizes” the battery by trickle recharging.

How to make the batteries perform longer

(1)Recharge the batteries before they become completely exhausted.

When you feel that the power of the tool becomes weaker, stop using the tool and recharge its battery. If you continue to use the tool and exhaust the electric current, the battery may be damaged and its life will become shorter.

(2)Avoid recharging at high temperatures.

A rechargeable battery will be hot immediately after use. If such a battery is recharged immediately after use, its internal chemical substance will deteriorate, and the battery life will be shortened. Leave the battery and recharge it after it has cooled for a while.

BEFORE USE

Check the work area to make sure that it is clear of debris and clutter.

Clear the area of unnecessary personnel. Ensure that lighting and ventilation is adequate.

OPERATION

1. Using the light equipped hook

WARNING: When using the hook, pay sufficient attention so that the main equipment does not fall. If the tool falls, there is a risk of accident.

19

Page 19
Image 19
Hitachi DS 18DMR, DS 14DMR Before USE, Operation, Using the light equipped hook, Revitalizing the battery trickle recharge