Displacement Pump ProConnect

Displacement Pump ProConnect

GH200/230/300 Only

(Figures 13-27)

See pump manual 311845 for pump repair.

5. (Fig. 15) Slide coupler cover (193) up to fully expose rod

 

 

 

 

 

couplers (179).

Removal

247

 

 

 

 

 

 

 

 

 

 

 

 

1. Flush pump.

193

179

2. Relieve pressure, page 7.

3. (Fig. 13) Remove suction hose (114).

ti8829a

FIG. 15

6. (Fig. 16) Remove rod couplers (179).

179

ti8827a

FIG. 13

4.(Fig. 14) Remove paint hose fitting (190) and paint hose (63) from pump fitting.

190 FIG. 16

7. (Fig 17) Remove pin.

63

ti8828a

FIG. 14

179

ti8830a

ti8831a

FIG. 17

18

311797F

Page 18
Image 18
Hitachi GH 300 important safety instructions Displacement Pump ProConnect, 190 FIG