Hitachi HV-F22F, HV-F31F operation manual See trigger operation details and timing chart

Models: HV-F22F HV-F31F

1 60
Download 60 pages 32.84 Kb
Page 32
Image 32

-Manual adjustment-

 

Setting value 8x0y0000 h

x2- LOW ACTIVE, 3- HIGH ACTIVE

 

y0- MDOE0, 1- MODE

Trigger mode polarity is switched at external signal values x and y.

See trigger operation details and timing chart (page 39).

(10) INITIALIZE

(CSR: F0F0 0000 h)

Return equipment to status at time of release from factory.

-Initialization-

Setting value 80000000 h

(11) MEMORY SAVE (EXECUTE)

(CSR: F0F0 0618 h)

Make back up of presently effective memory channels.

-BACK UP execute-

Setting value 80000000 h

(12) MEMORY SAVE (Ch SET)

(CSR: F0F0 0620 h)

Select channel carried out memory backup.

-channel set-

 

 

Setting value

x0000000 h

x: 1- ch1, 2- ch2, 3- ch3, 4- ch4

(13) CURRENT MEMORY

(CSR: F0F0 0624 h)

Loading memory channel designating data

-LOAD BACK UP-

 

 

Setting value

x0000000 h

x: 0- FACTORY SETUP, 1- ch1, 2- ch2, 3- ch3, 4- ch4

18

Page 32
Image 32
Hitachi HV-F22F, HV-F31F See trigger operation details and timing chart, Select channel carried out memory backup