d) (A.E) GATE line7-8

 

(CSR: F200 0088 h)

 

 

 

 

 

 

 

 

-Manual adjustment-

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting value 820xx0yy h

 

xx: LINE 7 ON/OFF bit map data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

yy: LINE 8 ON/OFF bit map data

 

 

 

 

 

 

(A.E) GATE line1-2 to line7-8 setting examples

 

 

 

 

 

 

 

 

 

 

 

 

 

Screen detect areas

 

Setting values corresponding to detect areas

 

 

 

 

 

 

 

 

 

 

 

Detect area (ON): 1 Non-detect area (OFF): 0

 

 

 

 

 

 

 

 

 

 

 

 

7

6

 

5

 

4

3

2

 

1

0

 

 

 

 

 

 

 

 

 

GATE line1-2 xx values

0

0

 

0

 

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

GATE line1-2 yy values

0

0

 

0

 

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

GATE line3-4 xx values

0

0

 

0

 

0

0

0

 

0

0

 

 

 

 

 

 

 

 

 

GATE line3-4 yy values

0

0

 

1

 

1

1

1

 

0

0

 

 

 

 

 

 

 

 

 

GATE line5-6 xx values

0

1

 

1

 

1

1

1

 

0

0

 

 

 

 

 

 

 

 

 

GATE line5-6 yy values

0

1

 

1

 

1

1

1

 

0

0

 

 

 

 

 

 

 

 

 

GATE line7-8 xx values

0

1

 

1

 

1

1

1

 

0

0

 

 

 

 

 

 

 

 

 

GATE line7-8 yy values

0

1

 

1

 

1

1

1

 

0

0

Values for setting the above map detection area

(A.E) GATE line1-2: 82 00 00 00 h

(A.E) GATE line3-4: 82 00 00 3C h

(A.E) GATE line5-6: 82 07 C0 7C h

(A.E) GATE line7-8: 82 07 C0 7C h