(5) Data frame error (Master transmission)

ENQ code (05H)

 

 

 

 

1

 

 

2

ACK code (06H)

 

 

 

 

 

 

 

4

Send data (ASCII code)

3

 

 

 

 

HITACHI

 

 

 

 

 

 

 

 

 

 

3 second

 

 

 

Send data (ASCII code)

elapse

 

 

 

 

 

Slave

 

 

5

 

 

 

3 second

(KP-F500PCL/SCL

 

 

 

Send data (ASCII code)

elapse

 

 

 

KP-FR500PCL/SCL)

 

 

 

 

Master (PC)

 

 

 

 

 

 

 

 

3 second

 

 

 

 

elapse

 

 

 

Send data (ASCII code)

6

 

 

 

 

Session starts when ENQ is sent from master to slave.

 

Slave acknowledges by returning ACK to master.

 

Master sends data.

 

 

 

For some reason, slave does not receive data.

 

Master does not receive acknowledgment to the send code and repeats the sequence every 3

 

seconds for 3 times.

 

 

 

If unsuccessful after 3 attempts, master aborts the sequence and ends communication.