4.VD reset

When external VD pulse is inputted, internal HD/VD is reset. External VD specification: 16.00 Hz or less

*Note: When external VD of 16.00 Hz or more is input, electronic shutter has an equation between external VD and 16.00 Hz.

VD input

(Low active) High Low

Data output

3H

VD

8H (*1)

FVAL

3H

VD output

0.3μs

*1:When partial scan, variable by start position of picture grabbing. 4H when vertical two pixel addition.

Input / Output signal

1. Input signal

The level of the trigger signal input to KP-F500PCL/SCL and KP-FR500PCL/SCL is as follows.

(1)Input from CameraLink cable LVDS level.

(2)Input from 12-pin connector

High level

: +2.5 to +5.0

V

Low level

: 0 to +0.3

V

2. Output signal

The level of the trigger signal output from KP-F500PCL/SCL and KP-FR500PCL/SCL is as follows.

High level

: +5V

Low level

: 0V

26