Command list
1. Send data (Setting command. Note: 1 to 7 and SUM need to be transformed into ASCII code)
|
|
|
| 1 | 2 | 3 | 4 | 5 | 6 |
| 7 |
|
|
| Item |
| STX | STATUS | ID NO. | AREA | RELATIVE |
| DATA |
| ETX | SUM | |
|
|
|
| ADDRESS | NO. |
|
|
|
| ||||
|
| OFF | 02 | 01 | FF | 01 | 04 | 00 | 00 |
| 00 | 03 | 28 |
| MODE | FIXED | 02 | 01 | FF | 01 | 04 | 01 | 00 |
| 00 | 03 | 27 |
| 1TRIG | 02 | 01 | FF | 01 | 04 | 02 | 00 |
| 00 | 03 | 26 | |
|
|
| |||||||||||
TRIGGER |
| VD CONT | 02 | 01 | FF | 01 | 04 | 04 | 00 |
| 00 | 03 | 24 |
POLARITY | POSITIVE | 02 | 01 | FF | 01 | 0F | 00 | 00 |
| 00 | 03 | 16 | |
|
| ||||||||||||
| NEGATIVE | 02 | 01 | FF | 01 | 0F | 01 | 00 |
| 00 | 03 | 15 | |
|
|
| |||||||||||
| SOURCE | 02 | 01 | FF | 01 | 05 | 00 | 00 |
| 00 | 03 | 26 | |
| 12pin | 02 | 01 | FF | 01 | 05 | 01 | 00 |
| 00 | 03 | 25 | |
|
|
| |||||||||||
|
| OFF | 02 | 01 | FF | 01 | 06 | 00 | 00 |
| 00 | 03 | 26 |
OUTPUT SIGNAL | FLASH OUT | 02 | 01 | FF | 01 | 06 | 01 | 00 |
| 00 | 03 | 25 | |
|
| VD | 02 | 01 | FF | 01 | 06 | 02 | 00 |
| 00 | 03 | 24 |
|
| OFF | 02 | 01 | FF | 01 | 08 | 00 | 00 |
| 00 | 03 | 24 |
|
| 1/16 | 02 | 01 | FF | 01 | 08 | 01 | 00 |
| 00 | 03 | 23 |
|
| 1/60 | 02 | 01 | FF | 01 | 08 | 02 | 00 |
| 00 | 03 | 22 |
|
| 1/100 | 02 | 01 | FF | 01 | 08 | 03 | 00 |
| 00 | 03 | 21 |
SHUTTER | PRESET | 1/250 | 02 | 01 | FF | 01 | 08 | 04 | 00 |
| 00 | 03 | 20 |
1/1000 | 02 | 01 | FF | 01 | 08 | 05 | 00 |
| 00 | 03 | 1F | ||
SPEED |
|
| |||||||||||
| 1/2000 | 02 | 01 | FF | 01 | 08 | 06 | 00 |
| 00 | 03 | 1E | |
(*1) |
|
| |||||||||||
| 1/10000 | 02 | 01 | FF | 01 | 08 | 07 | 00 |
| 00 | 03 | 1D | |
|
|
| |||||||||||
|
| 1/50000 | 02 | 01 | FF | 01 | 08 | 08 | 00 |
| 00 | 03 | 1C |
|
| VARIABLE (*2) | 02 | 01 | FF | 01 | 08 | FF | 00 |
| 00 | 03 | F8 |
| VARIABLE VALUE | MIN (1/100000(s)) | 02 | 01 | FF | 01 | 11 | 00 (*3) | 00 (*3) |
| 00 | 03 | 2A |
| (2Byte) (*2) | MAX (10(s)) | 02 | 01 | FF | 01 | 11 | 06 (*3) | 00 (*3) |
| 00 | 03 | 1E |
CONFIGURATION | BASE | 02 | 01 | FF | 01 | 12 | 00 | 00 |
| 00 | 03 | 29 | |
MEDIUM | 02 | 01 | FF | 01 | 12 | 01 | 00 |
| 00 | 03 | 28 | ||
|
|
| |||||||||||
|
| 8bit | 02 | 01 | FF | 01 | 14 | 00 | 00 |
| 00 | 03 | 27 |
DATA BIT | 10bit | 02 | 01 | FF | 01 | 14 | 01 | 00 |
| 00 | 03 | 26 | |
|
| 12bit | 02 | 01 | FF | 01 | 14 | 02 | 00 |
| 00 | 03 | 25 |
VD/FVAL | VD | 02 | 01 | FF | 01 | 15 | 00 | 00 |
| 00 | 03 | 26 | |
FVAL | 02 | 01 | FF | 01 | 15 | 01 | 00 |
| 00 | 03 | 25 | ||
|
|
| |||||||||||
|
| HD | 02 | 01 | FF | 01 | 16 | 00 | 00 |
| 00 | 03 | 25 |
HD/LVAL | LVAL | 02 | 01 | FF | 01 | 16 | 01 | 00 |
| 00 | 03 | 24 | |
|
| LVAL2 | 02 | 01 | FF | 01 | 16 | 02 | 00 |
| 00 | 03 | 23 |
GAIN (2Byte) | MIN (0) | 02 | 01 | FF | 01 | 0C | 00 (*4) | 00 (*4) |
| 00 | 03 | 19 | |
MAX (503/336) (*4) | 02 | 01 | FF | 01 | 0C | 01 (*4) | F7/50(*4) |
| 00 | 03 | FB/13 | ||
|
|
| |||||||||||
BLACK LEVEL | MIN (0) | 02 | 01 | FF | 01 | 17 | 00 (*5) | 00 |
| 00 | 03 | 24 | |
MAX (63) | 02 | 01 | FF | 01 | 17 | 3F (*5) | 00 |
| 00 | 03 | 0B | ||
|
|
| |||||||||||
VERTICAL 2 PIXEL | OFF | 02 | 01 | FF | 01 | 13 | 00 | 00 |
| 00 | 03 | 28 | |
ADDITION (*6) | ON | 02 | 01 | FF | 01 | 13 | 01 | 00 |
| 00 | 03 | 27 | |
| MODE | OFF | 02 | 01 | FF | 01 | 1E | 00 | 00 |
| 00 | 03 | 16 |
| ON (*6) | 02 | 01 | FF | 01 | 1E | 01 | 00 |
| 00 | 03 | 15 | |
|
|
| |||||||||||
PARTIAL | START | MIN (1) | 02 | 01 | FF | 01 | 1F | 00 | 01 |
| 00 | 03 | 14 |
SCAN | (2BYTE) (*7) | MAX (2058) | 02 | 01 | FF | 01 | 1F | 08 (*8) | 0A (*8) |
| 00 | 03 | FC |
| WIDTH | MIN (1) | 02 | 01 | FF | 01 | 20 | 00 | 01 |
| 00 | 03 | 29 |
| (2BYTE) (*7) | MAX (2058) | 02 | 01 | FF | 01 | 20 | 08 (*8) | 0A (*8) |
| 00 | 03 | 11 |
(*1) SHUTTER SPEED settings are effective only in the condition TRIGGER MODE is OFF or FIXED SHUTTER.
(*2) VARIABLE VALUE can be set only when VARIABLE is selected.
(*3) VARIABLE VALUE: selectable in the range from 0000 to 060016 (See page 5 to 6 about setting shutter speed).
(*4) GAIN: selectable in the range from 000016 to 01F716 :
(*5) BLACK LEVEL: selectable in the range from 0016 to 3F16.
(*6) VERTICAL 2 PIXEL ADDITION is only for
(*7) PARTIAL SCAN START/WIDTH can be set only when PARTIAL SCAN MODE is ON.
(*8) PARTIAL SCAN START/WIDTH: selectable in the range from 000116 to 080A16 and the sum total of START and WIDTH is 080A16 or less.
14