Command list

1. Send data (Setting command. Note: 1 to 7 and SUM need to be transformed into ASCII code)

 

 

 

 

1

2

3

4

5

6

 

7

 

 

 

Item

 

STX

STATUS

ID NO.

AREA

RELATIVE

 

DATA

 

ETX

SUM

 

 

 

 

ADDRESS

NO.

 

 

 

 

 

 

OFF

02

01

FF

01

04

00

00

 

00

03

28

 

MODE

FIXED

02

01

FF

01

04

01

00

 

00

03

27

 

1TRIG

02

01

FF

01

04

02

00

 

00

03

26

 

 

 

TRIGGER

 

VD CONT

02

01

FF

01

04

04

00

 

00

03

24

POLARITY

POSITIVE

02

01

FF

01

0F

00

00

 

00

03

16

 

 

 

NEGATIVE

02

01

FF

01

0F

01

00

 

00

03

15

 

 

 

 

SOURCE

CL-CC1

02

01

FF

01

05

00

00

 

00

03

26

 

12pin

02

01

FF

01

05

01

00

 

00

03

25

 

 

 

 

 

OFF

02

01

FF

01

06

00

00

 

00

03

26

OUTPUT SIGNAL

FLASH OUT

02

01

FF

01

06

01

00

 

00

03

25

 

 

VD

02

01

FF

01

06

02

00

 

00

03

24

 

 

OFF

02

01

FF

01

08

00

00

 

00

03

24

 

 

1/16

02

01

FF

01

08

01

00

 

00

03

23

 

 

1/60

02

01

FF

01

08

02

00

 

00

03

22

 

 

1/100

02

01

FF

01

08

03

00

 

00

03

21

SHUTTER

PRESET

1/250

02

01

FF

01

08

04

00

 

00

03

20

1/1000

02

01

FF

01

08

05

00

 

00

03

1F

SPEED

 

 

 

1/2000

02

01

FF

01

08

06

00

 

00

03

1E

(*1)

 

 

 

1/10000

02

01

FF

01

08

07

00

 

00

03

1D

 

 

 

 

 

1/50000

02

01

FF

01

08

08

00

 

00

03

1C

 

 

VARIABLE (*2)

02

01

FF

01

08

FF

00

 

00

03

F8

 

VARIABLE VALUE

MIN (1/100000(s))

02

01

FF

01

11

00 (*3)

00 (*3)

 

00

03

2A

 

(2Byte) (*2)

MAX (10(s))

02

01

FF

01

11

06 (*3)

00 (*3)

 

00

03

1E

CONFIGURATION

BASE

02

01

FF

01

12

00

00

 

00

03

29

MEDIUM

02

01

FF

01

12

01

00

 

00

03

28

 

 

 

 

 

8bit

02

01

FF

01

14

00

00

 

00

03

27

DATA BIT

10bit

02

01

FF

01

14

01

00

 

00

03

26

 

 

12bit

02

01

FF

01

14

02

00

 

00

03

25

VD/FVAL

VD

02

01

FF

01

15

00

00

 

00

03

26

FVAL

02

01

FF

01

15

01

00

 

00

03

25

 

 

 

 

 

HD

02

01

FF

01

16

00

00

 

00

03

25

HD/LVAL

LVAL

02

01

FF

01

16

01

00

 

00

03

24

 

 

LVAL2

02

01

FF

01

16

02

00

 

00

03

23

GAIN (2Byte)

MIN (0)

02

01

FF

01

0C

00 (*4)

00 (*4)

 

00

03

19

MAX (503/336) (*4)

02

01

FF

01

0C

01 (*4)

F7/50(*4)

 

00

03

FB/13

 

 

 

BLACK LEVEL

MIN (0)

02

01

FF

01

17

00 (*5)

00

 

00

03

24

MAX (63)

02

01

FF

01

17

3F (*5)

00

 

00

03

0B

 

 

 

VERTICAL 2 PIXEL

OFF

02

01

FF

01

13

00

00

 

00

03

28

ADDITION (*6)

ON

02

01

FF

01

13

01

00

 

00

03

27

 

MODE

OFF

02

01

FF

01

1E

00

00

 

00

03

16

 

ON (*6)

02

01

FF

01

1E

01

00

 

00

03

15

 

 

 

PARTIAL

START

MIN (1)

02

01

FF

01

1F

00

01

 

00

03

14

SCAN

(2BYTE) (*7)

MAX (2058)

02

01

FF

01

1F

08 (*8)

0A (*8)

 

00

03

FC

 

WIDTH

MIN (1)

02

01

FF

01

20

00

01

 

00

03

29

 

(2BYTE) (*7)

MAX (2058)

02

01

FF

01

20

08 (*8)

0A (*8)

 

00

03

11

(*1) SHUTTER SPEED settings are effective only in the condition TRIGGER MODE is OFF or FIXED SHUTTER.

(*2) VARIABLE VALUE can be set only when VARIABLE is selected.

(*3) VARIABLE VALUE: selectable in the range from 0000 to 060016 (See page 5 to 6 about setting shutter speed).

(*4) GAIN: selectable in the range from 000016 to 01F716 : KP-F500PCL/SCL. from 000016 to 015016 : KP-FR500PCL/SCL.

(*5) BLACK LEVEL: selectable in the range from 0016 to 3F16.

(*6) VERTICAL 2 PIXEL ADDITION is only for KP-F500PCL/SCL.

(*7) PARTIAL SCAN START/WIDTH can be set only when PARTIAL SCAN MODE is ON.

(*8) PARTIAL SCAN START/WIDTH: selectable in the range from 000116 to 080A16 and the sum total of START and WIDTH is 080A16 or less.

14