English
ADJUSTING THE NAILING DEPTH
[Only NR83A2 (with depth adjustment)]
WARNING
⬤Disconnect the air hose from the nailer before turning the adjuster.
To assure that each nail penetrates to the same depth, be sure that:
1)the air pressure to the Nailer remains constant (regulator is installed and working properly), and
2)the Nailer is always held firmly against the workpiece. If nails are driven too deep or shallow into the workpiece, adjust the nailing in the following order.
1DISCONNECT AIR HOSE FROM NAILER
Adjuster
15
Disconnect air hose
2If nails are driven too deep, turn the adjuster to the shallow side.
Adjustments are in
2Turn Adjuster
Too Deep | Flush |
If nails are driven too shallow, turn the adjuster to the deep side.
2Turn Adjuster
Too Shallow
Flush
3Stop turning the adjuster when a suitable position is
reached for a nailing test.
4Connect the air hose.
ALWAYS WEAR EYE PROTECTION.
Perform a nailing test.
5DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
— 15 —