3. Measurement Specifications

See “Appendix 2” for Standard Measurement Condition and Measurement Procedure

4. Environment Condition and Test

Operating Condition

Temperature

-10°C ~ 60°C

 

(Recommendation: -5°C ~ 50°C)

 

Humidity

20% ~ 60%

Storage Condition

Temperature

-40°C ~ 60°C

 

Humidity

0% ~ 90%

4.1 High Temperature Storage Test

In Storage condition at a temperature of 60°C for 72 hours, t hen leaving it at Normal Temperature for 8 hours, there will be no problem in performance.

4.2 Low Temperature Storage Test

In Storage condition at a temperature of -40°C for 72 hours, then leaving it at Normal Temperature for 8 hours, there will be no problem in performance.

5.Interface

5.1Pin Assignment

TTL Communication (10 Pin FFC Connector; Maker LinkWork 1.0mm Pitch, Upper Contact)

5.2 J204 - 10 Pin Connector

Pin

Name

I / O

Level

 

 

 

 

 

 

 

 

 

 

1

C Out

Output

Chroma Out

 

2

Y Out

Output

Luminance Out

 

3

Gnd

 

Video Ground

 

4

V Out

Output

Composite Video Output

 

5

12 V

Input

11.5 to 12.5 volts DC

 

6

Key 1

Input

 

 

 

 

 

 

7

Key 2

Input

 

 

 

 

 

 

8

RXD

Output

CMOS Level 5v (low: ≤ 0.8v, High: ≥ 3.7v

 

9

TXD

Input

CMOS Level 5v (low: ≤ 0.8v, High: ≥ 3.7v

 

10

Gnd

 

Power / Data Ground

 

 

 

5v

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.3Line In Pulse (Ex, FV)

0v

200nsec min

60 Hz ±0.25Hz

 

*The 10 pin Connector (JAE) over the camera module is used for manufacturing. (Not for user)