Hitachi X200 Standard Specifications, Phase 200V class, Phase 400V class, General Specifications

Models: X200

1 20
Download 20 pages 21.49 Kb
Page 4
Image 4

Standard Specifications

1-/3-phase 200V class

 

 

 

European Version

002SFEF2

004SFEF2

005SFEF2

007SFEF2

011SFEF2

 

015SFEF2

 

022SFEF2

 

-

 

-

-

Model X200-

 

 

US Version

002NFU2

004NFU2

-

007NFU2

-

 

015NFU2

 

022NFU2

 

037LFU2

 

55LFU2

075LFU2

 

 

 

JP Version

002LFRF2

004LFRF2

-

007LFRF2

-

 

015LFRF2

 

022LFRF2

 

037LFRF2

 

055LFRF2

075LFRF2

 

Applicable motor size, 4-pole kW(HP) *1

0.2(1/4)

0.4(1/2)

0.55(3/4)

0.75(1)

1.1(1.5)

 

1.5 (2)

 

2.2(3)

 

3.7(5)

 

5.5(7.5)

7.5(10)

 

Rated capacity

 

230V

0.5

1.0

1.1

1.5

1.9

 

2.8

 

3.9

 

6.3

 

9.6

12.7

Output Ratings

 

240V

0.5

1.0

1.2

1.6

2.0

 

2.9

 

4.1

 

6.6

 

9.9

13.3

 

 

 

 

 

 

Rated output current (A) *2

1.4

2.6

3.0

4.0

5.0

 

7.1

 

10.0

 

15.9

 

24.0

32.0

 

 

 

 

 

 

Overload capacity(output current)

 

 

 

 

150% for 60 sec.

 

 

 

 

 

 

 

Rated output voltage (V)

 

 

3-phase (3-wire) 200 to 240V (corresponding to input voltage)

 

 

 

 

 

 

 

 

 

 

 

SFEF: 1-phase 200 to 240V+10%, -15%, 50/60Hz ±5%

 

 

 

 

 

Rated input voltage (V)

 

 

 

 

NFU: 1-/3-phase 200 to 240V+10%, -15%, 50/60Hz ±5%

 

 

 

 

Input Rating

 

 

 

 

 

 

LFU/LFRF: 3-phase 200 to 240V+10%, -15%, 50/60Hz ±5%

 

 

 

Rated input current

 

SFEF2

3.1

5.8

6.7

9.0

11.2

 

16.0

 

22.5

 

-

 

-

-

 

(A)

 

NFU2/LFUF2/LFRF2

1.8

3.4

-

5.2

-

 

9.3

 

13.0

 

20.0

 

30.0

40.0

Enclosure *4

 

 

 

 

 

 

 

IP20

 

 

 

 

 

 

Cooling method

 

 

 

 

 

Self-cooling

 

 

 

 

 

Force ventilation

 

 

Integrated EMC filter

 

 

-SFEF2

 

 

 

 

EN61800-3 category C1 filter

 

 

 

 

 

 

 

 

-NFU2/LFU2/LFRF2

 

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zero phase Reactor

 

 

-LFRF2

 

 

 

 

Built-in

 

 

 

 

 

 

 

 

 

-SFEF2

0.8

1.0

1.5

1.5

2.4

 

2.4

 

2.5

 

-

 

-

-

Weight (kg)

 

 

-NFU2/LFU2

0.8

0.9

-

1.5

-

 

2.3

 

2.4

 

2.3

 

4.2

4.2

 

 

 

-LFRF2

0.8

0.9

-

1.1

-

 

2.2

 

2.4

 

2.4

 

4.2

4.2

3-phase 400V class

 

 

 

European Version

004HFEF2

007HFEF2

015HFEF2

022HFEF2

 

030HFEF2

040HFEF2

055HFEF2

075HFEF2

Model X200-

 

 

US Version

004HFU2

007HFU2

015HFU2

022HFU2

 

-

040HFU2

055HFU2

075HFU2

 

 

 

JP Version

004HFRF2

007HFRF2

015HFRF2

022HFRF2

 

-

037HFRF2

055HFRF2

075HFRF2

 

Applicable motor size, 4-pole kW(HP) *1

0.4(1/2)

0.75(1)

1.5 (2)

2.2(3)

 

3(4)

4(5)

5.5(7.5)

7.5(10)

 

Rated capacity

 

400V

1.0

1.7

2.6

3.8

 

5.4

5.9

9.0

11.1

Output Ratings

 

480V

1.2

2.0

3.1

4.5

 

6.4

7.1

10.8

13.3

 

 

 

Rated output current (A) *2

1.5

2.5

3.8

5.5

 

7.8

8.6

13.0

16.0

 

 

 

Overload capacity(output current)

 

 

 

150% for 60 sec.

 

 

 

 

Rated output voltage (V)

 

 

3-phase (3-wire) 380 to 480V (corresponding to input voltage)

 

 

Input Rating

Rated input voltage (V)

 

 

 

3-phase 380 to 480V +10%, -15%, 50/60Hz±5%

 

 

 

Rated input current (A)

 

2.0

3.3

5.0

7.0

 

10.0

11.0

16.5

20.0

Enclosure *4

 

 

 

 

 

 

 

IP20

 

 

 

Cooling method

 

 

 

Self-cooling

 

 

 

Force ventilation

 

 

Integrated EMC filter

 

 

-HFEF2

 

 

 

EN61800-3 category C2 filter

 

 

 

 

 

-HFU2/HFRF2

 

 

 

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

Zero phase Reactor

 

 

-HFRF2

 

 

 

 

Built-in

 

 

 

 

 

 

-HFEF2

1.5

2.3

2.4

2.4

 

2.4

2.4

4.2

4.2

Weight (kg)

 

 

-HFU2

1.4

2.2

2.3

2.3

 

-

2.3

4.2

4.2

 

 

 

-HFRF2

1.5

2.3

2.4

2.4

 

2.4

2.4

4.2

4.2

General Specifications

 

Item

 

General Specifications

 

Control method

 

Line-to-line sine wave pulse-width modulation (PWM) control

 

Output frequency range *5

 

0.5 to 400Hz

 

Frequency accuracy *6

 

Digital command :±0.01%, Analog command±0.4% (25 ±10˚C)

 

Frequency setting resolution

Digital: 0.1Hz, Analog: (max frequency)/1000

Control

Voltage/Frequency Characteristic

V/f control,V/f variable (constant torque, reduced torque)

Acceleration/deceleration time

0.01 to 3000 sec. (linear, sigmoid), two-stage accel./decel.

 

 

Starting torque *7

 

100%/6Hz

 

Carrier frequency range

 

2.0 to 12kHz

 

Protective functions

 

Over-current, over-voltage, under-voltage, overload, overheat, ground fault at power-on, input over-voltage, external trip, EEPROM error,

 

 

CPU error, USP error, Termister error, Driver error, Safety stop

 

 

 

 

Specification

 

10kohm input impedance, sink/source logic selectable

 

 

 

FW(Forward), RV(Reverse), CF1-CF4(Multispeed command), JG(Jogging), DB(External DC braking), SET(Second motor constants setting),

Input terminal

 

 

2CH(Second accel./decel.), FRS(Free-run stop), EXT(External trip), USP(Unattended start protection), SFT(Software lock), AT(Analog input

Functions

 

selection), RS(Reset), PTC(Thermistor input) *8, STA(3-wire start), STP(3-wire stop), F/R(3-wire fwd./rev.), PID(PID On/Off), PIDC(PID reset),

 

 

 

 

 

UP/DWN(Remote-controlled accel./decel.) , UDC(Remote-controlled data clearing), OPE(Operator control), ADD(ADD frequency enable), F-

 

 

 

TM(force terminal mode), RDY(quick start enable),S-ST(Special-Set 2nd Motor Data),EMR(Safety stop), NO(Not selected)

 

 

Specification

27V DC 50mA max open collector output, 1 terminals 1c output 250V AC/30V DC 2.5A relay (AL0, AL1, AL2 terminals)

 

Intelligent output terminal

 

RUN(run signal), FA1(Frequency arrival type 1 - constant speed), FA2(Frequency arrival type 2 - over-frequency), OL(overload advance

 

Function

notice signal), OD(Output deviation for PID control), AL(alarm signal), DC(Wire brake detect on analog input), FBV(PID Second Stage

Output signal

 

 

 

Output), NDC(ModBus Network Detection Signal), LOG(Logic Output Function), ODC(Option Card Detection Signal), LOC(Low load)

 

 

 

 

Analog output terminal

Specification

0 to 10V DC

 

Function

Analog Frequency monitor, analog current monitor

 

 

 

 

Specification

4-digits 7 segment LEDs

Operator

Display

Function

Parameter setting, output frequency, output current, scaled value of output frequency, trip history, I/O terminal condition, output

 

voltage. Rotation direction, PID Feedback, RON time, Power-on time.

 

 

 

 

Status LED Interface

 

Power, Alarm, Run, Prg, Hz and A Potentiometer, RUN, STOP/RESET, UP, DOWN, FUN and STR keys

 

 

Operator keypad

Up and Down keys / Value settings or analog setting via potentiometer on operator keypad

 

Frequency setting

External signal

0 to 10 V DC, 4 to 20 mA

Operation

 

Serial port

RS485 interface (Modbus RTU)

 

Operator Keypad

Run key / Stop key (change FW/RV by function command)

 

 

 

FW/RV Run

External signal

FW Run/Stop (NO contact), RV set by terminal assignment (NC/NO), 3-wire input available

 

 

Serial port

RS485 interface (Modbus RTU)

 

Operating temperature

 

-10 to 50˚C(carrier derating required for aambient temperature higher than 40°C), no freezing

 

Storage temperature

 

-20 to 65˚C

Environment

Humidity

 

20 to 90% RH

 

Vibration

 

5.9mm/s2 (0.6G) 10 to 55Hz

 

Location

 

Altitude 1,000 m or less, indoors (no corrosive gasses or dust)

 

Other functions

 

AVR (Automatic Voltage Regulation), V/f characteristic selection, accel./decel. curve selection, frequency upper/lower limit, 16 stage

 

 

multispeed, PID control, frequency jump, external frequency input bias start/end, jogging, cooling fan On/Off, trip history etc.

 

 

 

 

Coating color

 

Blue

 

Options

 

Remote operator with copy function (SRW-0EX), input/output reactors, DC reactors, radio noise filters, braking resistors, braking units, LCR filter, communication cables (ICS-1, 3)

 

 

 

 

 

Note 1: The applicable motor refers to Hitachi standard 3-phase motor (4-pole). When using other motors, care must be

 

taken to prevent the rated motor current (50/60 Hz) from exceeding the rated output current of the inverter.

 

Note 2: The output voltage decreases as the main supply voltage decreases (except when using the AVR function). In

 

any case, the output voltage cannot exceed the input power supply voltage.

 

Note 3: The braking torque via capacitive feedback is the average deceleration torque at the shortest

 

deceleration (stopping from 50/60 Hz as indicated). It is not continuous regenerative braking torque.

3

The average decel torque varies with motor loss. This value decreases when operating beyond 50 Hz.

If a large regenerative torque is required, the optional regenerative braking resistor should be used.

Note 4: The protection method conforms to JEM 1030.

Note 5: To operate the motor beyond 50/60 Hz, consult the motor manufacturer for the maximum allowable rotation speed.

Note 6: The output frequency may exceed the maximum frequency setting (A004 or A204) for automatic stabilization control.

Note 7: At the rated voltage when using a Hitachi standard 3-phase, 4pole motor.

Note 8: Only terminal 5 is assignable the PTC (thermistor) function.

Page 4
Image 4
Hitachi X200 manual Standard Specifications, Phase 200V class, Phase 400V class, General Specifications

X200 specifications

The Hitachi X200 series is a line of cutting-edge industrial drives designed to enhance operational efficiency and performance across various applications. Developed with advanced technologies, the X200 drives are geared toward providing seamless integration, superior control, and robust reliability in manufacturing environments.

One of the standout features of the Hitachi X200 is its exceptional control capabilities. The drive employs vector control technology, enabling precise and efficient motor control across a range of speeds. This allows users to achieve optimal performance in applications that require a high level of accuracy and responsiveness. The built-in auto-tuning function simplifies the setup process, adjusting parameters automatically to ensure that the drive operates at its best.

Another key characteristic of the X200 series is its energy efficiency. The drives are designed to minimize energy consumption while maximizing output. With features like energy-saving mode and advanced power management, operators can significantly reduce operational costs. This focus on sustainability is becoming increasingly important as industries strive to meet environmental regulations and improve their carbon footprint.

The X200 series also showcases robust communication capabilities. It supports multiple communication protocols, including Modbus, Profibus, and Ethernet/IP. This flexibility ensures that users can easily integrate the drives into existing automation systems and communicate seamlessly with other devices. Additionally, the drive supports remote monitoring and control, allowing for real-time performance tracking and adjustments from anywhere.

Reliability is paramount in industrial settings, and the Hitachi X200 does not disappoint. It is built with high-quality components that ensure durability and longevity even in harsh operating conditions. The drives have a wide operational temperature range and are designed to withstand vibrations, making them suitable for challenging environments.

Furthermore, the X200 series comes equipped with advanced safety features, including built-in motor overload protection and fault diagnosis capabilities. This ensures that any potential issues are identified promptly, minimizing downtime and improving overall reliability.

In conclusion, the Hitachi X200 series offers a comprehensive solution for industries looking to enhance their motor control and automation capabilities. With its advanced control technologies, energy efficiency, robust communication options, and high reliability, the X200 drives stand out as a top choice for modern industrial applications. These features combine to deliver not just performance but also a pathway toward greater operational efficiency and sustainability.