English
COLD WEATHER CARE
◯Do not store the Stapler in a cold weather environment.
Keep the Stapler in a warm area until beginning the work.
◯If the Stapler is already cold, bring it in a warm area
and allow the Stapler to warm up before use.
1 Reduce the air pressure to 40 psi (2.8 bar 2.8 kgf/ cm2).
2Remove all staples from the Stapler.
3Connect the air hose and
The lowered air pressure will be enough to free- fire the Stapler.
Slow speed operation tends to warm up the moving part.
CAUTION
⬤Do not
TESTING THE STAPLER
DANGER
⬤ Operators and others in work area MUST wear safety glasses with side shields which conforms to ANSI Z87.1 specifications.
WARNING
⬤Never use Stapler unless push lever is operating properly.
Before actually beginning the stapling work, test the Stapler by using the checklist below. Conduct the tests in the following order.
If abnormal operation occurs, stop using the Stapler and contact a Hitachi authorized service center immediately.
(1)DISCONNECT AIR HOSE FROM STAPLER. REMOVE ALL STAPLES FROM STAPLER.
☐ALL SCREWS MUST BE TIGHTENED. If any screws are loose, tighten them.
☐THE PUSH LEVER AND TRIGGER MUST MOVE
SMOOTHLY. Trigger
Push
Lever
Do not connect air hose
(2) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm2). Connect the air hose.
Do not load any staples in the Stapler.
☐THE STAPLER MUST NOT LEAK AIR.
Hold the Stapler downward and pull the trigger.
☐THE STAPLER MUST NOT OPERATE.
Pull Trigger
Push
Lever
(3)With finger off the trigger, depress the push lever against the workpiece.
☐THE STAPLER MUST NOT OPERATE. Do not pull Trigger
Depress
Push Lever
(4)Without touching the trigger, depress the push lever against the workpiece.
Pull the trigger.
— 10 —