– 18 –
Parameters MenuThe parameters Menu — Table 1 lists the parameter name, a short description, a list of possible values the parameter can have, the factory default value based on the specic dishwasher model and the security level required to access that parameter.

PARAMeTeRs MenU — TABle 1

Parameter
name
Description Model Possible
Values
Default
Value
security
Required
Conveyor speed Adjusts the speed of the conveyor in feet per
minute. Increasing the value can increase the
throughput of ware, but can decrease the ability
to sufciently clean difcult items, such as food
particles cooked onto pots and pans.
FT900
FT900D
FT900s
FT900sD
FT950
4 – 8.5
4 – 8.5
4 – 6.3
4 – 6.3
4 – 5
8.5
8.5
6.3
6.3
5
sO
Low FR Temp
Alarm
Enables or disables a visual alarm on the display that
indicates that Final Rinse water temperature is below the
NsF required minimum of 180°F (82°C). When enabled, a
message will display notifying the user of this condition.
However, machine operation will not change and ware will
continue to run through the machine as expected. When
disabled, there will be no extra message indicating a
low-temperture event; however, the temperature display will
still show the current Final Rinse water temperature.
Enabled
or
Disabled
Disabled M
superOp. Access Enables or disables the superOperator access level.
When enabled, this allows any user to modify values in
the parameters Menu that are marked as requiring only
sO security without entering a password. This can be
useful, for example, to allow the operator to adjust conveyor
speed based on the volume of dishes entering the dish
room without the need for intervention by a manager.
When disabled, the only operation allowed by any user is
the ability to enter the security Code and exit the menu.
No parameters are allowed to be modied.
Enabled
or
Disabled
Disabled M
Change Mgr. Code sets a new security Code for elevating access to the
Manager Level.
It is recommended to change this from the default value
and store the new code where all kitchen managers, but no
operators, can access it.
0000
to
8888
1001 M
Edit
Communications
setup?
Enters the Communications setup submenu, where settings
for the NAFEM Data protocol can be changed. please refer
to Communications setup Menu – Table 2 for more details.
M
save settings
and Exit?
Exits the parameters menu and returns to the main screen.
Any settings that were changed are saved and most
become active immediately.
(If one or more settings are not active immediately, a
message will display indicating that you need to cycle
power to make them active.)
sO
Cancel settings
and Exit?
Exits the parameters menu and returns to the main screen.
Any settings that were changed are cancelled and revert
back to the previous saved values.
sO