– 19 –
Communications setup MenuThe Communications setup Menu — Table 2 lists the parameter name, a short description, a list of possible values the parameter can have, the factory default value based on the specic dishwasher model and the security level required to access that parameter.COMMUnICATIOns seTUP MenU –— TABle 2
Parameter
name
Description Possible
Values
Default
Value
security
Required
NAFEM Dp Baud Adjusts the baud rate of communication between the
dishwasher and a NAFEM Data protocol (NDp) Gateway
(sold separately). This must match the setting in the NDp
Gateway.
Refer to documentation that came with the NDp Gateway
for instructions on where to nd this value.
9600
to
38,400
9600 M
NAFEM Dp ID Adjusts the machine-specic ID for use on a NAFEM
Data protocol network.
Each device on the network must have a unique ID.
please refer to any documentation that came with other
NDp-compliant devices to verify that all IDs on the network
are unique.
1
to
247
5 M
Exit to params? Exits the Communications setup menu and returns to the
parameters menu. Any settings that were changed are
only saved by choosing the SAvE SEttingS And Exit? option
on the parameters menu.
Changing communication values typically requires the
machine power to be cycled.