Hobart ML-126826 Installation Codes And Standards, In the United States of America, In Canada

Models: HPX3 ML-126826

1 12
Download 12 pages 52.84 Kb
Page 4
Image 4
INSTALLATION CODES AND STANDARDS

INSTALLATION CODES AND STANDARDS

The steamer must be installed in accordance with:

In the United States of America:

1.State and local codes.

2.National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

In Canada:

1.Local codes.

2.Canadian Electric Code, CSA C22.2 (latest edition). Copies may be obtained from The Canadian Standard Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3.

LEVELING

The steamer must be level for proper operation. Place a carpenter's level on top of the steamer. Level the steamer front to back and side to side by turning the adjustable feet.

ELECTRICAL CONNECTIONS

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH THE APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH TO INDICATE YOU ARE WORKING ON THE CIRCUIT.

When making electrical connections, use copper wire suitable for at least 200°F (90°C). The steamer must be grounded. The wiring diagram is located on the inside of the right panel.

Steamers wired for 1-phase can be changed to 3-phase, or vice versa, by relocating the jumper wires on the terminal block, as shown on the wiring diagram.

ELECTRICAL DATA

Model

Volts

kW

Amp @ 1-PH

Amp @ 3-PH

 

 

 

 

 

 

208

*6

28.9

N/A

 

9

43.3

25.0

 

 

 

 

 

 

 

HPX3

240

*6

25.0

N/A

9

37.5

21.7

 

 

 

 

 

 

 

 

480

*6

NA

N/A

 

9

10.9

 

 

 

 

 

 

 

 

 

208

*10

48.1

N/A

 

15

72.2

41.7

 

 

 

 

 

 

 

HPX5

240

*10

41.7

N/A

15

62.5

36.1

 

 

 

 

 

 

 

 

480

*10

NA

N/A

 

15

18.1

 

 

 

 

 

 

 

 

*See single phase 2/3 connections on wiring diagram.