MAINTENANCE

MAINTENANCE

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT BEFORE BEGINNING ANY MAINTENANCE PROCEDURE.

LUBRICATION

Planetary

The planetary oil should be checked periodically. To check, DISCONNECT ELECTRICAL POWER SUPPLY and remove the Drip Cup-Splash Guard, which is secured by three screws. Remove the fill plug (Fig. 5). Oil should be even with the bottom of the fill plug hole. If the oil is not at the proper level, slowly add the recommended planetary lubricant until the proper level is achieved. Replace the fill plug and the Drip Cup-Splash Guard.

Planetary Fill Plug

Planetary

Drain Plug

Lift Screw

Planetary Seal

Slideways

PL-41558-1

Fig. 5

A drain plug (Fig. 5) is located on the bottom of the planetary. Should draining become necessary, remove the Drip Cup-Splash Guard and place a suitable catch pan under the drain plug. Remove the drain plug, allow the oil to completely drain, and replace the drain plug. Remove the fill plug and pour in 6 fluid ounces of the recommended planetary lubricant. Replace the Fill Plug and the Drip Cup- Splash Guard. Contact your local Hobart Service Office for the recommended planetary lubricant.

Planetary Seal

Occasionally, the planetary seal (Fig. 5) may become dry and begin to squeak. To correct this, work a little lubrication under the lip of the seal.