MAINTENANCE
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT BEFORE BEGINNING ANY MAINTENANCE PROCEDURE.
LUBRICATION
Planetary
The planetary oil should be checked periodically. To check, DISCONNECT ELECTRICAL POWER SUPPLY and remove the Drip
Planetary Fill Plug
Planetary
Drain Plug
Lift Screw
Planetary Seal
Slideways
Fig. 5
A drain plug (Fig. 5) is located on the bottom of the planetary. Should draining become necessary, remove the Drip
Planetary Seal
Occasionally, the planetary seal (Fig. 5) may become dry and begin to squeak. To correct this, work a little lubrication under the lip of the seal.
– 13 –