TROUBLESHOOTING
SYMPTOMS |
| POSSIBLE CAUSES |
|
|
|
Mixer will not start. | 1. | Gear shift lever is between gears (not fully engaged). |
| 2. Electrical power supply is interrupted. Circuit breaker or | |
|
| disconnect switch is off, or fuse is blown. |
| 3. | Mixer or attachment is overloaded. |
| 4. | Bowl is not all the way up. |
| 5. | Wire Cage Assembly is not in the |
|
| position. |
|
|
|
Agitator touches bowl. | 1. | Bowl clamp(s) not closed. |
| 2. | Improper agitator clearance — see MAINTENANCE |
|
| for adjustment procedure. |
| 3. | Bowl clamp(s) improperly adjusted — see |
|
| MAINTENANCE for adjustment procedure. |
|
| |
Planetary seal squeaks. | 1. Seal requires occasional lubrication — see | |
|
| MAINTENANCE. |
|
|
|
SERVICE
If service is needed on this equipment, contact your local Hobart Service Office.