OPERATION

OPERATION

WARNING: MOVING BEATER IN BOWL, KEEP HANDS, CLOTHING, AND UTENSILS OUT WHILE IN OPERATION, DO NOT USE WITHOUT INTERLOCKED GUARD.

Every M802 and V1401 mixer is equipped with either an Electro-Mechanical Timer Control (described on this page) or a Programmable Timer Controller (described on pages 7 – 9). Also, become familiar with the other operating parts (Fig. 2) and their functions, which are referenced throughout the OPERATION section (pages 6 – 12).

The Bowl Guard must be in position or the mixer will not operate. Refer to page 11.

If the Bowl Support is not all the way up, the mixer will not operate unless the START button is held in.

 

 

 

 

 

 

 

 

 

Power Bowl Lift Lever

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Timer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Start Button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Clutch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Oil Level Gauge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gear Shift Lever

 

 

 

 

Drip Cup

Stop Button

 

 

 

 

 

 

 

 

 

Apron

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bowl Guard

 

Bowl Handle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Agitator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alignment Pin

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bowl Clamp

 

 

 

 

 

Bowl

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bowl Truck (accessory)ELECTRO-MECHANICAL TIMER CONTROLS (when equipped)

PL-40999-1

Fig. 2

ELECTRO-MECHANICAL TIMER CONTROLS (when equipped)

The START button is used to start the mixer.

The STOP button is used to stop the mixer.

The TIMER is used in conjunction with the START button for timed mixing operations and will stop the mixer when a preset time has elapsed.

For timed mixing — Place the clutch lever on STOP and set the gear shift lever at the desired speed. Set the timer at the desired time and press the START button to start the motor. Move the clutch lever to RUN to start mixing. (Clutch Lever and Gear Shift Lever are described on page 10.)

If you need to stop the mixer before the time has elapsed, move the clutch lever to STOP and press the STOP button. To resume mixing, press the START button and move the clutch lever to RUN.

For non-timed mixing — Place the clutch on STOP and set the gear shift lever at the desired speed. Set the timer on HOLD, press the START button to start the motor, and move the clutch lever to RUN to start mixing. To stop the mixer, move the clutch lever to STOP and press the STOP button.