DISC SELECTION
DISC SELECTION WS-40/80
The amount of hardness removed (in compensated gpg) will be based on the amount of brine and the meter disc selected.
1.Determine the compensated hardness. This requires a hardness test and an iron test on raw water at the application site. Compensated hardness is calculated by multiplying the ferrous iron (in ppm) by 3 and adding it to the grains of hardness.
2.To test the water supply, use the water analysis test kit available through Pro Products Inc. The recommended kit is #2401 Field Analysis Kit. To order the test kit contact Pro Products at
3.Determine the salt setting. The salt setting is determined by taking the compensated hardness (calculated in step 1 above) and using the specification table for model
4.Verify the float cup setting. Use specifications for the
Specifications | ||
Salt usage / generation | 1.0 lbs. | 1.4 lbs. |
Capacity | 2,527 grains | 4,818 grains |
Efficiency | 2,527 gr./lb. | 3,442 gr./lb. |
Dosing | 5.5 lbs./cu. ft. | 3.5 lbs./cu. ft. |
Float cup setting | 6.25" | 6.5" |
Disc Number | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
Compensated Hardness * | 4 | 8 | 11 | 15 | 19 | 23 | 27 | 30 | |
Gallons Between | 9.1 | 9.1 | 9.1 | 9.1 | 8.4 | 6.6 | 5.4 | 4.4 | |
Regeneration | |||||||||
|
|
|
|
|
|
|
| ||
Rregeneration Gallons | 583 | 282 | 194 | 146 | 117 | 97 | 83 | 73 | |
(min.) @ 15 psig | |||||||||
|
|
|
|
|
|
|
| ||
* Compensated hardness in gpg = Hardness + (3 x Fe in mg/l) |
|
|
|
|
Disc Number | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | |
Compensated Hardness * | 5 | 11 | 17 | 22 | 27 | 32 | 35 | 40 | |
Gallons Between | 10.2 | 10.2 | 10.2 | 10.2 | 10.2 | 8.3 | 6.7 | 5.5 | |
Regeneration | |||||||||
|
|
|
|
|
|
|
| ||
Rregeneration Gallons | 732 | 366 | 244 | 183 | 146 | 122 | 105 | 92 | |
(min.) @ 15 psig | |||||||||
|
|
|
|
|
|
|
| ||
* Compensated hardness in gpg = Hardness + (3 x Fe in mg/l) |
|
|
|
|
F25404 Rev. A (0413) |