WS-40/80 Hobart Compact Water Softener Installation Instructions - INSTALLATION

33. Continue slowly until internal water flow is heard at softener valve. The softener will automatically run through a regeneration. This process should be repeated in 12 to 15 minutes to flush other resin tank.

34. Check for plumbing leaks.

35. Check unit for proper operation.

Fig. 17

27.Check for proper operation by pressing the recessed red button on bottom of salt alarm controller. If controller is operating properly - the indicator light will flash and an audible tone will be heard.

Fig. 18

28.

29.Add a clean grade of salt at this time. Higher grades of Pelletized Salt for impurities and solubility should be used.

NOTE: Do not use rock salt or solar salt.

30.Open inlet valve slowly allowing system to pressurize.

31.Water and air will be expelled from drain until system is completely pressurized.

32.A manual regeneration should be started to purge air and color from softening system. This is done by pushing down on actuator with a Phillips screwdriver and rotating clockwise slowly until pressure is felt.

Page 7 of 10

 

F25404 Rev. A (0413)