WS-40/80 Hobart Compact Water Softener Installation Instructions - INSTALLATION

15.Insert tubing provided into the overflow port on the back of the softener and run drain lower than the cabinet connection to provide a gravity drain in the event of a internal cabinet leak.

Fig. 10

16.Review the meter disc selection chart and the water analysis provided. If no water analysis is provided test the water supply.

17.To test the water supply, use the water analysis test kit available through Pro Products Inc. The recommended kit is #2401 Field Analysis Kit. To order the test kit contact Pro Products at 800- 285-9176 or visit www.ProProducts.com.

18.Determine the correct number disc. DISC SELECTION

NOTE: Both the WS-40 and the WS-80 have a #4 meter disc installed at the factory. If this is not correct disc for your application, locate meter disc kit and

REPLACE DISC.

19.Remove brine valve assembly from cabinet to set float cup.

A.Disconnect tubing from brine valve elbow by holding collet and pulling tubing straight away.

Fig. 11

B.Remove the brine valve assembly by lifting straight up.

C.Set it on a flat surface, to mesure height of float cup.

D.Measure from bottom of brine valve to top of float cup.

Fig. 12

Page 5 of 10

 

F25404 Rev. A (0413)