2-8. 115 Volts AC Duplex Receptacle
Y Turn Off power before con- necting to receptacle.
1 115 V AC Receptacle
Receptacle is protected from over- load by circuit breaker CB1 (see Section
Power output is shared between this receptacle and the Remote 14 receptacle (see Section
1
Ref.
2-9. Electrical Service Guide
|
| 60 Hz |
|
| 50 Hz |
| ||
|
|
|
|
|
|
|
| |
Input Voltage | 200 | 230 | 460 | 575 | 220 | 380 | 415 | |
|
|
|
|
|
|
|
| |
Input Amperes At Rated Output | 105 | 91 | 46 | 36 | 88 | 51 | 47 | |
|
|
|
|
|
|
|
| |
Max Recommended Standard Fuse Or Circuit Breaker Rating In |
|
|
|
|
|
|
| |
Amperes |
|
|
|
|
|
|
| |
Circuit Breaker1 , | 125 | 110 | 50 | 45 | 110 | 60 | 50 | |
Normal Operating 3 | 150 | 125 | 70 | 50 | 125 | 80 | 70 | |
Min Input Conductor Size In AWG/Kcmil | 4 | 6 | 8 | 10 | 6 | 8 | 8 | |
|
|
|
|
|
|
|
| |
Max Recommended Input Conductor Length In Feet (Meters) | 116 | 103 | 271 | 284 | 99 | 194 | 232 | |
(35) | (31) | (83) | (87) | (30) | (59) | (71) | ||
| ||||||||
|
|
|
|
|
|
|
| |
Min Grounding Conductor Size In AWG/Kcmil | 6 | 6 | 8 | 10 | 6 | 8 | 8 | |
|
|
|
|
|
|
|
|
Reference: 1999 National Electrical Code (NEC)
1Choose a circuit breaker with
2
3“Normal Operating” (general purpose – no intentional delay) fuses are UL class “K5” (up to and including 60 amp), and UL class “H” ( 65 amp and above).