4-3. Troubleshooting
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Trouble |
| Remedy | |
|
|
|
|
|
No weld output; unit completely | Place line disconnect switch in On position (see Section | |||
inoperative. |
|
| ||
|
|
|
|
|
|
|
| Check and replace line fuse(s), if necessary (see Section | |
|
|
|
|
|
|
|
| Check for proper input power connections (see Section | |
|
|
|
|
|
|
|
| Check for proper jumper link position (see Section | |
|
|
|
|
|
No weld output; fan on. | If using remote control, place Output (Contactor) switch in Remote 14 position, and make sure remote | |||
|
|
| control is connected to Remote 14 receptacle. If remote is not being used, place Output (Contactor) | |
|
|
| switch in On position. | |
|
|
|
|
|
|
|
| Check, repair, or replace remote control. | |
|
|
|
|
|
|
|
| Unit overheated. Allow unit to cool with fan On (see Section | |
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check control board PC1. | |
|
|
|
|
|
Unit provides only maximum or | Have Factory Authorized Service Agent check control board PC1 and hall device HD1. | |||
minimum weld output. |
|
| ||
|
|
|
|
|
Weld output always above or always | Have Factory Authorized Service Agent check control board PC1 and hall device HD1. | |||
below set value. |
|
| ||
|
|
|
|
|
Erratic or improper weld output. | Use proper size and type of weld cable (see Section | |||
|
|
|
|
|
|
|
| Clean and tighten all weld connections. | |
|
|
|
|
|
|
|
| Check position of Output Selector switch (see Section Figure | |
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check control board PC1 and hall device HD1. | |
|
|
|
|
|
Fan not working. | Check for anything blocking fan. | |||
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check fan motor. | |
|
|
|
|
|
No control of weld output. | If using remote control, place Amperage/Voltage control switch in Remote 14 position, and make sure | |||
|
|
| remote control is connected to Remote 14 receptacle. If remote is not being used, place switch in | |
|
|
| Panel position. | |
|
|
|
|
|
|
|
| Have Factory Authorized Service Agent check control board PC1. | |
|
|
|
|
|
No 115 volts ac output from duplex | Reset circuit breaker CB1 (see Section | |||
receptacle or Remote 14 receptacle. |
|
| ||
|
|
|
|
|
No 24 volts ac output at Remote 14 re- | Reset circuit breaker CB2 (see Section | |||
ceptacle |
|
| ||
|
|
|
|
|
Wandering arc – poor control of | Reduce gas flow rate. | |||
direction of arc. |
|
| ||
|
|
|
|
|
|
|
| Select proper size tungsten. | |
|
|
|
|
|
|
|
| Properly prepare tungsten. | |
|
|
|
|
|
Tungsten electrode oxidizing and not | Shield weld zone from drafts. | |||
remaining bright after conclusion of |
|
| ||
weld. |
|
| ||
|
|
|
|
|
|
|
| Increase postflow time. | |
|
|
|
|
|
|
|
| Check and tighten all gas fittings. | |
|
|
|
|
|
|
|
| Properly prepare tungsten. | |
|
|
|
|
|
|
|
| Check for water in torch, and repair torch if necessary. See torch Owner’s Manual. | |
|
|
|
|
|
|
|
|
|