2-10. Placing Jumper Links And Connecting Input Power

200 VOLTS

230 VOLTS

 

460 VOLTS

L

L

L

L

L

L

 

 

 

 

S-083 566-C

230 VOLTS

 

460 VOLTS

 

575 VOLTS

L

L

L

L

L

L

 

 

 

 

 

S-010 587-B

220 VOLTS

 

380 VOLTS

 

415 VOLTS

L

L

L

L

L

L

S-131 783-A

1

Tools Needed:

3/8 in

3/8, 1/2, 7/16 in

Check input voltage available at site.

1 Jumper Link Label

Check label – only one is on unit.

2 Jumper Links

Move jumper links to match input voltage.

3 Input And Grounding

Conductors

Select size and length using

Section 2-9.

 

4 Line Disconnect Device

 

Select type and size of overcurrent

 

protection using Section 2-9.

 

Reinstall side panel.

 

Y Special installation may be

2

required where gasoline or

volatile liquids are present –

 

 

see NEC Article 511 or CEC

 

Section 20.

GND/PE

Earth Ground

4

L2 (V)

L1 (U)

3

ST-130 173-K

OM-318 Page 14

Page 18
Image 18
Hobart Welding Products 300 AC manual Placing Jumper Links And Connecting Input Power, Special installation may be, Section