4-5. Installing Ether Cylinder (Optional Ether Starting Aid)

1

2

3 4

5

6

YStop engine.

YImproper handling or expo- sure to ether can harm your health. Follow manufactur- er’s safety instructions on cylinder.

YDo not use Ether Starting Aid while engine is running.

Open side door(s).

1Ether Cylinder

2Nozzle

Remove cover and clean cylinder nozzle.

3Clamp

4Fitting

5Cap

6Valve

Remove cap and clean fitting. Install cylinder on fitting. Tighten clamp.

.After installing cylinder, wait at least 10 minutes before using to let ether particles settle and prevent atomizer plugging.

Put cap on fitting when cylinder is removed.

ether1 12/96 – ST-153 382-A / Ref. ST-188 448

4-6. Connecting To Weld Output Terminals

3

2

Open left side door.

1 Bracket

Route cables through bracket.

2Positive (+) Weld Output Terminal

3Negative (–) Weld Output Ter- minal

For Stick welding Direct Current Electrode Positive (DCEP), con- nect work cable to (–) terminal and electrode holder cable to (+) terminal.

For Direct Current Electrode Nega- tive (DCEN), reverse cable connections.

If equipped with optional polarity switch, connect electrode holder cable to Electrode (–) terminal and work cable to Work (+) terminal.

For FCAW welding, connect work cable to (–) terminal and wire feeder cable to (+) terminal.

1

Close door.

Tools Needed:

3/4 in

Ref. ST-800 162-A

OM-480 Page 16

Page 20
Image 20