SECTION 2 – INTRODUCTION

2-1. Specifications

 

 

 

 

RMS Amps Input at Rated Load

 

 

 

Voltage

Amperage

Max. Open-

Output, 60 Hz 3-Phase at NEMA Load

 

 

Rated Output at

Voltages and Class I Rating

 

 

Range in

Range in

Circuit

 

 

 

 

 

 

 

60% Duty Cycle

CV Mode

CC Mode

Voltage

230 V

460 V

575 V

KVA

KW

 

 

 

 

 

 

 

 

 

300 A at 32 VDC, 3-Phase

10–35 V

5–400 A

90 VDC

30.5

18.9

15.2

12.2

11.6

 

 

 

 

(0.21*)

(0.10*)

(0.08*)

(0.09*)

(0.04*)

 

 

 

 

 

 

 

 

 

225 A at 29 VDC, 1-Phase

 

 

 

47.4

24.5

– –

11.3

7.6

 

 

 

 

(0.34*)

(0.14*)

 

(0.09*)

(0.04*)

 

 

 

 

 

 

 

 

 

*While idling

**See Section 3-5 for additional information.

2-2. Duty Cycle And Overheating

Duty Cycle is percentage of 10 min- utes that unit can weld at rated load without overheating.

If unit overheats, output stops, a Help message is displayed (see Section 5-2), and cooling fan runs. Wait fifteen minutes for unit to cool. Reduce amperage or voltage, or duty cycle before welding.

Y Exceeding duty cycle can damage unit and void warranty.

60% Duty Cycle

6 Minutes Welding

4 Minutes Resting

Overheating

 

0

A or V

 

15

 

OR

Minutes

Reduce Duty Cycle

 

sduty1 5/95 / SA-207 877

OM-2208 Page 9

Page 13
Image 13
Hobart Welding Products OM-2208 manual Introduction, Specifications, Duty Cycle And Overheating